+86 18068001229 - Transformer e kentsoeng ka palo e le 'ngoe ea mohato o le mong
- Transformer e kentsoeng ka mohato o le mong oa Pad
- Transformer e nang le mekhahlelo e meraro ea Pad
- Transformer ea Kabo e Itširelelitsoeng ka Oli ea Mekhahlelo e Meraro
- Transformer ea Matla
- Seteishene se senyenyane
- Transformer ea Mofuta o Omileng
01
Li-Transformer tsa Oli tsa 220kVA tse Sebetsang Haholo Bakeng sa Litšebeliso tse Boima
Likarolo tsa Sebopeho
Core
Meqomo ea tšepe ea silicon e phutholohileng ka mokhoa o batang e nang le ho kenella ho phahameng e nang le ho thibela lera ho fokotsa tahlehelo ea motlakase oa eddy.
Moralo oa maoto a mahlano oa mekhahlelo e meraro ho fokotsa impedance ea lefela-tatelano le ho thibela li-harmonics.
.Mabili a moea
Ho Koenya ha Motlakase o Phahameng: Leqeba la foile ea koporo le nang le sethibelo sa ho kenya pampiri sa Nomex.
Ho Koenya ha Voltage e Tlase: Sebopeho sa cylindrical sa mekhahlelo e mengata bakeng sa khanyetso e ntlafalitsoeng ea potoloho e khuts'oane.
.Tanka le ho Pholisa
Moralo oa ONAN o nang le phallo ea oli ea tlhaho 'me ha o na lifene tsa kantle, o loketse ho kenngoa kantle.
Mapheo a radiator a nang le masenke a kentswe ka tankeng bakeng sa ho qhala mocheso ka katleho.
.Sistimi ea ho kenya mocheso
Oli ea diminerale (kapa oli ea ester e sireletsang tikoloho) e fana ka ho thibela ho bola, ho pholisa le ho timela ha arc.
Boemo ba ho ntsha metsi ka karolo e itseng ≤50pC (ho latela IEC 60076).




Likopo
Kabo ea Matla a Liindasteri
Kabo ea motlakase o mahareng (10kV ho isa ho 0.4kV) lifekthering, merafong le lifemeng tsa tšepe.
E tšehetsa ho jara boima ba nako e khuts'oane (mohlala, lionto tsa motlakase, lik'hamphani tse qalang tsa enjene).
.Mehaho ea Khoebo
Kabo ea motlakase bakeng sa mabenkele a maholo, litora tsa liofisi le lihotele.
.Meralo ea motheo
Liteishene tsa literene, boema-fofane le lifeme tsa ho hloekisa metsi a litšila.
.Libaka tse hole
E sebetsa ka botshepehi libakeng tse mongobo o phahameng, tse lerōle, kapa tse feto-fetohang mocheso.
Melemo ea Bohlokoa
Tšepo e Phahameng
Tanka e koetsoeng ka botlalo e thibela ho oxidation le tšilafalo ea oli.
Bokhoni bo matla ba ho mamella potoloho e kgutshwane (e latela GB/T 1094.5).
.Tlhokomelo e Tlase
Moralo o se nang tlhokomelo o nang le boemo ba oli le mocheso oa nako ea sebele.
.E bolokang litšenyehelo
Matsete a tlase a pele le tahlehelo e fokolang ea matla a ts'ebetso.
.Likhetho tse Sireletsang Tikoloho
E fumaneha ka oli ea ester e bolang (mohlala, FR3) bakeng sa ho latela RoHS.
Tataiso ea Khetho
Yuniti ka 'ngoe e feta litekong tse matla, ho kenyeletsoa:
Liteko tsa ho hanyetsa insulation le tsa motlakase oa impulse.
Litekanyo tsa tahlehelo ea mojaro le tahlehelo e se nang mojaro.
Netefatso ea ho mamella potoloho e khuts'oane.
E netefalitsoe ke ISO 9001, ISO 14001, le KEMA bakeng sa ho latela melao ea lefats'e.
Tataiso ea Khetho
Litšobotsi tsa Mojaro
Netefatsa mofuta oa mojaro (o tsitsitseng khahlanong le o feto-fetohang).
Lekola litlhoko tsa ho jara boima ba motlakase ka nako e khuts'oane (mohlala, lionto tsa motlakase tsa arc).
.Maemo a Tikoloho
Bophahamo ba limithara tse ≤1,000 (ho hlokahala ho feta moo).
Mocheso o tikolohong: -25℃ ho isa ho +45℃ (ho pholisa ho ntlafalitsoeng bakeng sa libaka tsa tropike).
.Ho latela melao
E fihlela disetifikeiti tsa GB 1094 (Chaena), IEC 60076 (tsa matjhaba), le tsa indasteri e ikgethileng (mohlala, ATEX bakeng sa sepakapaka se phatlohang).
Ho kenya le ho hlokomela
Litlhoko tsa ho kenya
Motheo o bataletseng o nang le sebaka sa ≥1m mahlakoreng 'ohle bakeng sa ho qhala mocheso.
Khanyetso ea ho thella fatše ≤4Ω; moralo o arohaneng oa tšireletso ea lehalima.
.Tlhokomelo ea Kamehla
Hlahloba boemo ba oli, 'mala le ho dutla ha metsi likhoeli tse ling le tse ling tse 6.
Leka ho hanyetsa ho thibela mocheso selemo le selemo o sebedisa megohmmeter ya 2,500V.
.Ho rarolla mathata
Ho futhumatsa ho feta tekano: Hlahloba ho thibana ha radiator kapa meroalo e sa tloaelehang.
Tlhahlobo ea Chromatography ea Oli: Fumana matšoao a pele a ho ntšoa ha oli ka hare kapa ho senyeha ha insulation.



Hobaneng u re khetha
JIEZOU POWER, moqapi oa litsebi, moetsi le mohlomi oa tharollo ea sistimi ea motlakase lefatšeng ka bophara, e thehiloe ka selemo sa 1989, e nka sebaka sa lisekoere-mithara tse 200,000.
JIEZOU POWER, haholo-holo e laola merero ea gridi ea motlakase, 500KV EPC, setsi sa motlakase oa metsi sa 230KV, seteishene sa motlakase sa 115KV, jj.
Feme ea JIEZOU POWER e ka hlahisa transformer ea mofuta oa oli le mofuta o omileng oa kabo, transformer ea matla ea max 500KV 480MVA, GIS, switchgear, substation, e ipapisitse le maemo a ANSI/IEEE/DOE2016/CSA/IEC60076.
JIEZOU POWER e fumana setifikeiti sa ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TLALEHO EA TEKANO EA MOFUTA ka ho latellana. Ho fihlela ka selemo sa 2023, lik'hamphani tsa makala le lifeme tsa lefats'e ka bophara li abuoa United States, Canada, Dubai, Dominican Republic, Philippines, lifeme le lik'hamphani tsa makala a Chaena li motseng oa BengBu, motseng oa FengYang, motseng oa HaiAn, motseng oa TaiZhou, motseng oa SuZhou, motseng oa ShenYang, motseng oa FoShan.
Ha re sheba bokamoso, pono ea JIEZOU POWER ke ho ba mofani oa tharollo ea sistimi ea motlakase ea tšepahalang ka ho fetisisa, ho rarolla liphephetso tse potlakileng ka ho fetisisa tsa taolo ea matla Lefatšeng, ho potlakisa phetoho ea polanete ho ea ho eneji e nchafatsoang. E le hore bohle ba ka ba le bophelo bo nang le khabone e tlase le bo khanyang haholoanyane. Ho fihlela sena, re tla etsa sohle se matleng a rona ho etsa boiteko.



Botsa Hona Joale!
Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.








