Leave Your Message

Mekhoa ea Grid ea Mekhahlelo e Meraro e Tšoarellang e Koetsoeng ka Oli

Transformer ea kabo e qoelitsoeng ka oli ea mekhahlelo e meraro ke tharollo e matla le e sebetsang hantle bakeng sa ho theola motlakase oa motlakase o nang le motlakase o phahameng ho ea maemong a ka sebelisoang marangrang a kabo ea motlakase. E etselitsoe ts'ebetso e tsoelang pele libakeng tse hlokang matla, li-transformer tsena li sebelisa oli e thibelang mocheso bakeng sa ho pholisa le ho thibela motlakase, ho netefatsa ts'epahalo, ho phela nako e telele le ho boloka litšenyehelo lits'ebetsong tsa bolulo, khoebo le indasteri. Li entsoe ho fihlela maemo a machaba (IEC, IEEE), li-transformer tsa rona li beha polokeho pele, bokhoni le botsitso.

    Litšobotsi tsa Bohlokoa le Melemo

    Ho Pholisa le ho Tšoarella ka Botlalo
    Ka ho qoelisoa ka oli ea boleng bo holimo e sireletsang mocheso, transformer e qhala mocheso hantle (ho pholisa ha ONAN/ONAF), e boloka ts'ebetso e ntle esita le tlas'a meroalo e boima. Oli e boetse e sebetsa e le insulator, e ntlafatsa polokeho ea motlakase le ho fokotsa ho tsofala.
    .Ho Tšepahala ho Holimo le Tlhokomelo e Tlase​​
    Kaho e tiileng e nang le mapheo a koporo le litsamaiso tse tsoetseng pele tsa ho thibela oli ea pampiri li netefatsa ho hanela khatello ea mocheso, mongobo le lipotoloho tse khutšoane. Litlhoko tse fokolang tsa tlhokomelo li etsa hore e be ntle bakeng sa libaka tse hole kapa tse thata ho fihlelleha.
    .Moralo o Monyenyane le o Monyenyane
    E fumaneha ka tekanyo ea motlakase ho tloha ho 11kV ho isa ho 33kV le bokhoni bo fihlang ho 5 MVA, ka litlhophiso tsa mekhahlelo e le 'ngoe kapa e meraro. Boholo bo kopaneng bo nolofatsa ho kenngoa liteisheneng tse nyane tsa litoropo, lirapeng tsa indasteri, kapa marang-rang a mahaeng.
    .Tlhokomelo e Bohlale (E ikgethelang)​​
    Li-sensor tse sebelisang IoT (ha ho hlokahale) li fana ka lintlha tsa nako ea sebele mabapi le mocheso oa oli, maemo a mojaro, le ho lemoha liphoso, ho nolofalletsa tlhokomelo e boletsoeng esale pele le ho fokotsa nako ea ho sebetsa.
    .E Sireletsa Tikoloho le ho Boloka Litšenyehelo​
    Ts'ebetso e lerata le tlase (
    Phetoho e Phahameng ea Phetoho e Iketselitsoeng ka Oli ea Cooper 10001Phetoho e Phahameng ea Phetoho e Ileng ea Koenngoa ka Oli ea Cooper 10002Phetoho e Phahameng ea Oli ea Cooper e Immeng ka Oli 10003
    Sistimi ea Grid e Tšoarellang e Koetsoeng ka Oli Mehato e Meraro
    • Sistimi ea Grid e Tšoarellang e Koetsoeng ka Oli Mehato e Meraro1
    • Sistimi ea Grid e Tšoarellang e Koetsoeng ka Oli Mehato e Meraro2
    • Sistimi ea Grid e Tšoarellang e Koetsoeng ka Oli Mehato e Meraro3
    • Sistimi ea Grid e Tšoarellang e Koetsoeng ka Oli Mehato e Meraro4
    • Sistimi ea Grid e Tšoarellang e Koetsoeng ka Oli Mehato e Meraro5
    • Sistimi ea Grid e Tšoarellang e Koetsoeng ka Oli Mehato e Meraro6
    Transformer e qoelitsoeng ka oli ea Cooper01

    Likopo

    Marangrang a Bolulo: Ho theola motlakase o mahareng (11kV/33kV) ho isa ho 230/400V bakeng sa malapa.
    .Liindasteri le Khoebo: Phepelo e tsitsitseng ea motlakase bakeng sa lifeme tsa tlhahiso, litsi tsa data le mabenkele a maholo.
    .Kopanyo e ka Nchafatsoang: Ho hokahanya mapolasi a letsatsi/moea le li-grid tse nang le motlakase o tlase.
    .Phetisetso ea Motlakase Mahaeng: Moralo o tšoarellang bakeng sa libaka tse hole kapa tse thata.

    Litlhaloso tsa Tekheniki

    Mefuta ea Motlakase: 11kV ho isa ho 33kV (motlakase o mahareng).
    .Bokgoni: 500 kVA ho isa ho 5,000 kVA.
    .Makgetlo: 50Hz/60Hz.
    .Ho pholisa: ONAN (Oli ea Moea oa Tlhaho oa Oli) kapa ONAF (Oli ea Moea oa Tlhaho o qobelloang).
    .Bokgoni: ≥98% ha e jarisitsoe ka botlalo (e netefalitsoe ke IEC 61378).

    Netefaletso ea boleng

    Teko e matla e netefatsa ho latela maemo a lefats'e:
    Liteko tsa matla a dielektri bakeng sa botšepehi ba ho thibela ho ruruha.
    Litekanyo tsa tahlehelo ea mojaro le ho phahama ha mocheso.
    Netefatso ea ho mamella potoloho e khuts'oane.
    E netefalitsoe ke ISO 9001 (boleng), ISO 14001 (tikoloho), le KEMA bakeng sa polokeho le botshepehi.

    Hobaneng re ka re Khetha?

    Lilemo tse 30+ tsa Botsebi: Meralo e pakiloeng bakeng sa maemo a fapaneng a leholimo le a ts'ebetso.
    .Netweke ea Tšehetso ea Lefatše ka Bophara: Lihlopha tsa tšebeletso tsa lehae le thuso ea botekgeniki ea 24/7.
    .Litheko tse Tlhōlisanoang: Litharollo tse ka atolosoang tse etselitsoeng litlhoko tsa tekanyetso le ts'ebetso.

    Litharollo tse Ikhethileng

    Meralo e Ikhethileng: Bakeng sa mocheso o feteletseng, libaka tse senyang, kapa libaka tse nang le litšisinyeho tsa lefatše.
    .Lintlafatso tsa Polokeho ea Matla: Likiti tsa ntlafatso bakeng sa litsamaiso tsa khale.
    Transformer e qoelitsoeng ka oli ea Cooper02Transformer e qoelitsoeng ka oli ea Cooper03Transformer e qoelitsoeng ka oli ea Cooper04Transformer e qoelitsoeng ka oli ea Cooper05

    Melemo ea sehlahisoa

    1. Lisebelisoa tsa Bohlokoa le Moralo oa ho Fetola
    Lisebelisoa tsa Bohlokoa
    Li-cores tsa Alloy tsa Amorphous:
    Tahlehelo ea tšepe e tlase haholo (70–80% e tlase ho feta tšepe ea silicon ea setso), e fokotsang tšenyo ea matla le litšenyehelo tsa ts'ebetso.
    Ho kenella ha metsi ka bongata le ho thibela motlakase ho batlang ho se na letho ho fokotsa lerata le ho thothomela, e leng se loketseng libaka tsa bolulo le tsa indasteri.
    Tšepe ea Silicon e Metsi a Koahetsoeng ke Lijo-thollo (CRGO):
    Li-lamination tse khaotsoeng ka laser kapa tse nang le mehato li fokotsa tahlehelo ea hona joale ea eddy, li fihlella maemo a katleho ho fihlela ho 98.5%.
    Tekanyo e ntlafetseng ya dijo-thollo e ntlafatsa bongata ba flux ya makenete bakeng sa ditshebediso tsa motlakase o phahameng (mohlala, 11kV–33kV).
    Moralo oa ho Fetoha
    Mabili a Foil a nang le ho Pholisa ha Oli:
    Mabili a koporo kapa a aluminium a fokotsa phallo ea ho lutla le matla a potoloho e khuts'oane. Ho potoloha ha oli ka har'a liphaephe tse kobehang ho ntlafatsa ho qhalana ha mocheso.
    Mealo ea conductor e kopaneng e fokotsa khatello ea motlakase oa ho potoloha lipakeng tsa li-turn le ho ntlafatsa ho mamella potoloho e khuts'oane.
    Li-winding tsa terata tsa Litz tse nang le mekhahlelo:
    Terata ea Litz ea likhoele tse ngata e fokotsa litlamorao tsa letlalo le bohaufi, e fokotsa khanyetso ea AC le tahlehelo maemong a maqhubu a phahameng.
    Sebopeho se Senyenyane sa Motheo sa Maoto a Mararo:
    Moralo o lekanang o leka-lekanya phallo ea makenete, o fokotsa tahlehelo ea tatellano ea zero le ho ntlafatsa ho tšoana ha mocheso.
    .2. Mekhoa ea ho kenya mocheso
    Sethibela-mafu se kopantsoeng sa oli le pampiri:
    Pampiri ea boleng bo holimo ea cellulose e tšetsoeng ka oli e sireletsang mocheso (mohlala, oli ea diminerale ea naphthenic kapa paraffinic) e fana ka matla a dielectric ho fihlela ho 300 kV BIL.
    E kopanya botsitso ba mocheso (e mamella mocheso ho fihlela ho 140°C) le ho hanyetsa mollo.
    Sekoahelo sa Epoxy Resin (Sehokelo sa Mofuta o Omileng):
    Resin ea epoxy e hanelang ho ntša metsi ka karolo e itseng bakeng sa ho koaheloa ha coil, e eketsang ho hanyetsa mongobo le tšilafalo.
    ​Sesebelisoa se Ntlafalitsoeng sa Nano:
    Metswako ya epoxy e tletseng silika e ntlafatsa nako ya bophelo ya ho ntsha metsi ka karolo ya 30–50%, e leng se loketseng dibakeng tse lebopong la lewatle kapa tsa diindasteri.
    .3. Tsamaiso ea Thermal​
    Oli-Tlhaho-Ho Pholisetsa Moea (ONAN):
    Pholiso e sa sebetseng ka li-radiator le convection ea oli ea tlhaho, e loketse ts'ebetso e tsoelang pele ha ho na le meroalo e lekantsoeng.
    Ho Pholisa Moea ka Matla (OFAF):
    Lifene tse laoloang ke mocheso li ntlafatsa ho qhalana ha mocheso, e leng se nolofalletsang bokgoni ba ho jara boima ba 120% bakeng sa nako e kgutshwane.
    Pholiso e Thusoang ke Pompo ea Oli (OFWF):
    Lipompo tsa potoloho ea oli le lifene tse qobelloang moeeng li ntlafatsa phetiso ea mocheso bakeng sa liteishene tse nyane tsa litoropo tse nang le baahi ba bangata.
    Tlhokomelo e Bohlale ea Thermal:
    Li-sensor tsa mocheso tse kentsoeng le litsamaiso tse sebelisang IoT li qala lialamo, ho tima ha mojaro, kapa ho kenya tšebetsong ho pholisa ho thibela ho senyeha ha insulation.
    .4. Moralo le Tšireletso ea Meaho
    Tanka e Matla le Sekoahelo​
    Litanka tse Hanelang Mafome:
    Matlo a tšepe a galvanized kapa a aluminium a nang le masela a polyurethane/phofo a hanela ho senyeha ha mahlaseli a kotsi a UV, ho fafatsa letsoai le ho pepesehela lik'hemik'hale.
    Ho Tiisoa ka Seaparo se Chesang:
    Litanka tse tjheseditsweng kapa tse nang le dibolte tse nang le digasket tsa EPDM di thibela ho dutla ha oli le ho kena ha mongobo, e leng se netefatsang hore di sebetsa ntle le tlhokomelo ka mashome a dilemo.
    Kalafo ea ho Thibela ho Senyeha:
    Mekhoa ea tšireletso ea cathodic le lipekere tse sa senyeheng ke mafome li eketsa bophelo ba tsona maemong a leholimo a nang le asiti kapa a mongobo.
    Likarolo tsa Polokeho
    Li-valve tsa ho imolla khatello:
    Ho ntša likhase ka bohona nakong ea liphoso tsa ka hare (mohlala, lipotoloho tse khutšoane), ho thibela ho phatloha ha tanka.
    Sistimi ea ho Boloka Oli:
    Litanka tsa li-conservator kapa li-conservator tse koetsoeng li fokotsa ho kopana ha oksijene, li fokotsa ho oxidation le ho thehoa ha seretse.
    Tšireletso ea ho phahama ha metsi:
    Li-arrester tse kopantsoeng tsa zinki oxide (MOA) le li-capacitor tsa surge li thibela liphetoho tse bakoang ke lehalima.
    .5. Mesebetsi e Tsoetseng Pele​
    Sistimi ea Tlhokomelo ea Maemo (CMS):
    Li-sensor li latela mocheso oa oli, tlhahlobo ea khase e qhibilihisitsoeng (DGA), maemo a mojaro, le ho ntšoa ha karolo e itseng ea oli, e leng se nolofalletsang tlhokomelo e boletsoeng esale pele ka SCADA.
    Bafetoleli ba Tap ba Lahliloeng (OLTC):
    Phetoho ea pompo e tsamaisoang ke AI e ntlafatsa taolo ea motlakase tlas'a meroalo ea gridi e feto-fetohang, e fokotsa tahlehelo ea matla ka ho fihla ho 5%.
    Mekhoa e Mecha e Sireletsang Tikoloho:
    Lioli tse sireletsang mocheso tse thehiloeng ho bio (mohlala, maro a ester) tse nang le bofokoli bo phahameng le ho cha ho fokolang, tse lumellanang le maemo a IEC 62721.
    ​Litšebeliso tsa Bohlokoa le Mekhoa ea Nakong e Tlang​
    Kabo ea Liindasteri le ea Litoropo:
    Lifeme tsa motlakase tse nang le matla a mangata (500kVA–5MVA), mehaho ea khoebo, le metse e bohlale.
    Kopanyo ea Matla a Nchafatsang:
    E loketse liteishene tse nyane tsa polasi ea moea/letsatsi le li-microgrid, tse tšehetsang phallo ea motlakase e shebaneng le mahlakore a mabeli.
    Tsoelo-pele ea Nakong e Tlang:
    Li-Transformer tsa Boemo bo Tiileng (SSTs): E nolofalletsa phetoho ea DC-DC le ho tenyetseha ha gridi bakeng sa litsamaiso tsa eneji tse arotsoeng ka thoko.
    ​Sethibela-mollo se Ipholisang: Lisebelisoa tsa nanocomposite li lokisa liphoso tse nyane tsa dielectric ka boikemelo.
    Kakaretso
    Li-Transformer tsa Kabo tse Kenngoeng ka Oli tsa Mekhahlelo e Meraro lia ipabola ka li-core tse sa lahleheng haholo, tsamaiso e tsoetseng pele ea mocheso, le litsamaiso tsa polokeho tse nang le mekhahlelo e mengata. Motsoako oa tsona oa bokhoni, bokhoni ba ho atolosa le ho mamella li etsa hore li be tsa bohlokoa bakeng sa li-grid tsa motlakase tsa sejoale-joale, ha mekhoa e mecha e kang oli e thehiloeng linthong tse phelang le bohlale.
    Transformer e qoelitsoeng ka oli ea Cooper06Transformer e qoelitsoeng ka oli ea Cooper07Transformer e qoelitsoeng ka oli ea Cooper08Transformer e qoelitsoeng ka oli ea Cooper09

    Botsa Hona Joale!

    Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.

    Leave Your Message