Transformer e kentsoeng ka karolo e le 'ngoe ea phase—15KVA

Litekanyetso tsa Voltage ea Motheo: 12470 Delta V
Litekanyetso tsa Voltage ea Bobeli: 120/240V
BOEMO BA HO THEPA HA HV: ±2*2.5%
MOFUTA OA KHOKANO: Ii6
MOFUTA: Transformer e kentsoeng ka palo
E NE E LE: 95/30kV
Maemo: IEEE C57.12.20, ANSI C57.12
Kopo: Bongata le kabo

    Tlhaloso ea Sehlahisoa

    JZP Transformer e ikhethile ka ho hlahisa di-transformer tse 15 kVA tse kentsweng palong e le nngwe tse latelang ka thata maemo a maholo a matjhaba, ho kenyeletswa le IEEE C57.12.00, IEEE C57.12.20, Ditlhoko tsa Katleho ya DOE-2016, CSA C2.1 & C2.2, le CSA C802.1. Re susumetswa ke boitlamo bo sa thekeseleng ba bokhabane, re fana ka ditharollo tse ikgethileng tse reretsweng ho tsamaisana hantle le ditlhaloso tsa hao tse ikgethang tsa tekheniki.
    Ho sa tsotelehe boemo ba motlakase kapa tikoloho ea ts'ebetso eo u e hlokang, tšepa JZP Transformer ho fana ka tharollo e nepahetseng e etselitsoeng litlhoko tsa hau tse ikhethileng. Khotsofalo ea hau, e kopantsoeng le botšepehi bo sa sekisetseng ba li-transformer tsa rona, e ntse e le motheo oa boinehelo ba rona ba ho fana ka boleng bo ikhethang.
    Ho netefatsa ts'ebetso ea ho tlisa thepa e boreleli le e theko e tlase, re hlophisitse le ho paka li-transformer tsohle ka hloko hore li lekane hantle ka har'a setshelo se le seng sa 40HQ, re nolofatsa tsamaiso ea thepa le ho fokotsa litšenyehelo tsa lipalangoang ka kakaretso.
    Ka ho khetha li-transformer tsa JZP, moreki a ka kholiseha qetong ea hae ea ho tsetela lisebelisoa tsa motlakase tsa maemo a holimo, a tšepisa ts'ebetso e sa bapisoeng le poloko ea matla. Boitlamo bona ba ho sebetsa hantle le botsitso bo tsamaisana le sepheo sa rona sa ho kenya letsoho tikolohong ea matla e tala le e nang le boikarabelo bo eketsehileng.
    Transformer e kentsoeng ka lipoleiti ea 15kVA ea 21.6kV
    Re hlahisa DL-15/21.6/0.24(0.12), transformer ea boleng bo holimo ea 15 kVA e kentsoeng palong e le 'ngoe e entsoeng ka hloko le ka boikhohomoso ke JZP Transformer. Transformer ena e fihlela maemo a thata a IEEE Std C57.12.00 le IEEE Std C57.12.20, e netefatsang ts'ebetso e ikhethang le polokeho.
    Ka tekanyo e phahameng ea motlakase ea 21.6 kV le tekanyo e tlase ea motlakase ea 240V (120V), DL-15/21.6/0.24(0.12) e fetola motlakase ka katleho ho sebetsana le lits'ebetso tse fapaneng. Taolo ea eona e pharaletseng ea motlakase e tloha ho 21600V ho isa ho 22680V e tiisa tlhahiso ea motlakase e tsitsitseng le e tsitsitseng, e nolofalletsang ts'ebetso e tšepahalang esita le tlas'a meroalo e feto-fetohang.
    Ho fana ka ho thibela le ho sireletsa ka matla, transformer e ithorisa ka BIL (Basic Insulation Level) ea 125 kV bakeng sa motlakase o phahameng le 30 kV bakeng sa motlakase o tlase, e sireletsang khahlanong le ho phahama ha motlakase le ho netefatsa ho tšoarella ha nako e telele.
    15kVA 21
    Transformer e kentsoeng ka lipoleiti ea 15kVA 14.4kV
    Ha re hlahisa JZP-15/14.4(24.94)/0.24(0.12), transformer e kentsoeng palong e le 'ngoe ea 15 kVA e entsoeng ka boikhohomoso le ho etsoa ke JZP Transformer.
    E na le motlakase o phahameng oa 14.4 kV le motlakase o tlase oa 240V (120V), tekanyo ea matla ea 15 kVA. DL-15/14.4(24.94)/0.24(0.12) e netefatsa phetoho ea motlakase e sebetsang hantle le e tšepahalang ho fihlela litlhoko tse fapaneng tsa motlakase. Li-winding tse phahameng le tse tlase tsa motlakase li entsoe ka aluminium e tšoarellang nako e telele, e netefatsang ts'ebetso e phahameng le bophelo bo bolelele.
    Transformer e entsoe ka polarity e eketsehileng, e netefatsang ho lumellana ho se nang sekoli le ts'ebetso e ntlafetseng tsamaisong ea hau ea kabo ea matla.
    Ka mefuta e fapaneng ea taolo ea motlakase ho tloha ho 13680V ho isa ho 15120V, transformer ena e tiisa tlhahiso ea motlakase e tsitsitseng le e tsitsitseng, e fana ka ts'ebetso e ntle ka ho fetisisa tlas'a maemo a fapaneng a mojaro. BIL ea eona e khahlang (Boemo ba Motheo ba Insulation) ea 95 kV le 30 kV e netefatsa tšireletso e matla khahlanong le maqhubu a motlakase, e ntlafatsang ts'epo le polokeho ea transformer.
    15kVA 14
    Transformer e kentsoeng ka lipoleiti ea 15kVA 14.4kV
    Mokelikeli o thibelang mocheso o sebediswang ke oli ya diminerale ya boleng bo hodimo, ha e na PCB, e kgothaletsa tshebetso e bolokehileng le e sireletsang tikoloho. Sistimi ya ho phodisa e sebedisa mokgwa wa ONAN (Oil Natural Air Natural), e fedisa mocheso ka katleho le ho boloka bokgoni ba transformer.
    Ho feta moo, transformer ea 15kVA ea 14.4 kV e tla e na le li-bushing tse peli tsa motlakase o phahameng le li-bushing tse tharo tsa motlakase o tlase, tse fanang ka likhetho tse tenyetsehang tsa khokahano. Li-bushing tsa motlakase o tlase li tlatselletsoa ka li-bar tsa koporo tse sitsitsoeng fatše, ho netefatsa polokeho e ntlafalitsoeng nakong ea ts'ebetso.
    Bakeng sa lits'ebetso tsa mekhahlelo e meraro, li-transformer tse tharo tsa 14.4 kV tse kentsoeng ka palo e le 'ngoe li ka kopanngoa ka katleho ho fana ka matla a 24.94 kV, ho khotsofatsa litlhoko tsa litlhophiso tse fapaneng tsa indasteri le tsa lits'ebeletso.
    Tlaleho ea Teko ea Transformer e Kenngoeng ka Lipalo tse 10kVA6
    Transformer e kentsoeng ka lipoleiti ea 15kVA 7.2kV
    Ha re hlahisa DL-15/7.2(12.47)/0.24(0.12), ke transformer e kentsweng palong e le nngwe e entsweng le ho etswa ke JZPTransformer. Transformer ena e na le bokgoni bo matla ba 15 kVA, e leng se etsang hore e be ntle bakeng sa ditshebediso tse fapaneng. Ka tekanyo ya motlakase ya mantlha ya 7.2 kV (12.47 kV) le tekanyo ya motlakase ya bobedi ya 120V (240V), transformer ena e netefatsa phetoho e sebetsang hantle ya motlakase ho fihlela ditlhoko tse fapaneng tsa motlakase.
    Ho amohela dikgokelo le ditshebediso tse fapaneng, DL-15/7.2(12.47)/0.24(0.12) e tla e na le di-bushing tse pedi tsa motlakase o phahameng le di-bushing tse tharo tsa motlakase o tlase, tse nang le meralo ya ho thella ha motlakase o tlase bakeng sa polokeho e ntlafetseng.
    Ka mefuta e tsotehang ea taolo ea motlakase oa mekhahlelo e tlohang ho 6840V ho isa ho 7560V, transformer ena e tiisa taolo ea motlakase e tšepahalang le e tsitsitseng, e netefatsang kabo e tsitsitseng ea motlakase holim'a meroalo e fapaneng. Ho feta moo, DL-15/7.2(12.47)/0.24(0.12) e bonts'a ho tenyetseha, kaha li-transformer tse tharo tsa mohato o le mong tsa moralo ona li ka hokahanngoa habonolo ho etsa transformer ea mekhahlelo e meraro ea 12.47 kV, e sebeletsang mefuta e mengata ea lits'ebetso tsa indasteri le tsa lits'ebeletso.
    Tlaleho ea Teko ea Transformer e Kenngoeng ka Lipalo tse 10kVA6
    Transformer e kentsoeng ka lipoleiti ea 15kVA ea 19.2kV
    DL-25/19.92/0.24(0.12), ke transformer e ikhethang ea 15 kVA ea mohato o le mong, e entsoeng ka boikhohomoso ke JZP Transformer, 'me e latela maemo a thata a IEEE C57.12.20 le ANSI C57.12. Transformer ena e etselitsoe ho fana ka ts'ebetso e phahameng le ts'epo, e fihlelang litlhoko tse fapaneng tsa litsamaiso tsa sejoale-joale tsa kabo ea matla. Transformer ea 15kVA e na le depolarization 'me e sebelisa sehlopha sa vector sa Iio, e netefatsa phallo ea motlakase e sebetsang hantle le e se nang sekoli, le ho ntlafatsa ts'ebetso le botsitso ka kakaretso marangrang a kabo.
    Tlaleho ea Teko ea Transformer e Kenngoeng ka Lipalo tse 10kVA6
    Tlaleho ea Teko ea Transformer e Kenngoeng ka Lipalo tse 10kVA
    Ho JZP Transformer, boleng bo ka pele ho ts'ebetso ea rona ea tlhahiso. Transformer e 'ngoe le e 'ngoe e kentsoeng palong ea mohato e feta tekong e thata le e felletseng ea kamehla pele e tloha fekthering ea rona. Re khomarela melaoana e tiileng ea taolo ea boleng ho netefatsa hore transformer e 'ngoe le e 'ngoe e fihlela maemo a holimo a indasteri le ho feta litebello tsa bareki.
    Nakong ea teko ea kamehla, litsebi tsa rona tse nang le boiphihlelo li hlahloba le ho lekola ts'ebetso ea transformer ka hloko, polokeho le ts'epo. Liparamente tsa bohlokoa tse kang taolo ea motlakase, khanyetso ea ho futhumatsa, tahlehelo ea mojaro, tahlehelo ea mojaro, le impedance li hlahlojoa ka botlalo ho netefatsa ts'ebetso e phethahetseng ea transformer.
    Ke feela ka mora ho pasa teko e thata ya kamehla le ho fihlela ditekanyetso tsohle tsa boleng, transformer e nkuwa e tshwaneleha bakeng sa ho paka le ho romela thepa. Mokgwa ona o hlokolosi o netefatsa hore bareki ba rona ba fumana feela ditransformer tse ntle ka ho fetisisa le tse tshepahalang ka ho fetisisa tse tsamaellanang hantle le ditlhoko tsa bona tse ikgethang.
    Tlaleho ea Teko ea Transformer e Kenngoeng ka Lipalo tse 10kVA6