Transformer ea Matla ea Mekhahlelo e 3 ea 35MVA 115kV

Litekanyetso tsa Voltage ea Motheo: 115kV
Litekanyetso tsa Voltage ea Bobeli: 13.8kV
BOEMO BA HO THEPA HA HV: 115kV ± 8 × 0.625%
MOFUTA OA KHOKANO: YNd1
MOFUTA: Phetoho ea matla ea pompo e jarolloang ka mojaro
E NE E LE: 450/110kV
Maemo: IEEE
Kopo: Matla a Macha
Tekanyetso ea Matla: 20,500/27,200/35,000kVA
Mokhoa oa ho Pholisa: ONAN/ONAF1/ONAF2

    Tlhaloso ea Sehlahisoa

    Transformer ea Matla ea 35MVA 115kV ea Mekhahlelo e 3, ke sesebelisoa sa motlakase sa sejoale-joale se etselitsoeng ho sebeletsa lits'ebetso tsa bohlokoa mererong ea matla a nchafatsoang. E hahiloe ho fihlela maemo a holimo a ts'ebetso, ts'epo le ts'ebeliso e ntle ea matla, ho netefatsa ts'ebetso e ntle ka ho fetisisa lits'ebetsong tsa matla a tloaelehileng le a nchafatsoang.
    Likarolo tsa Bohlokoa le Tshebetso
    Ho latela IEEE C57.12.00: Transformer ea 35MVA 115kV e latela maemo a indasteri ea machaba, e netefatsa boleng le ts'ebetso e phahameng.
    Tahlehelo e Tlase le Bokgoni bo Phahameng: E entsoe ka tahlehelo e tlase ea mantlha le koporo, transformer ena e fokotsa tšebeliso ea matla haholo, e tlatsetsa ho tšoarelleng le ho boloka litšenyehelo ka katleho.
    Lerata le Fokotsang ho Ntša Mollo ka Karolo: E entsoe bakeng sa ho ntša metsi ka karolo e tlase (PD) le ho ntša lerata, e netefatsa ts'ebetso e khutsitseng ha e ntse e boloka botsitso ba nako e telele.
    Khanyetso ea Potoloho e Khutšoanyane: Transformer e etselitsoe ho mamella maqhubu a mangata a phoso, e ntlafatsa polokeho le ho tšoarella ha sistimi ka kakaretso.
    Moralo o se nang ho dutla: Ka kaho e matla, transformer ena e etselitsoe ho thibela ho dutla ha oli, ho ntlafatsa polokeho ea tikoloho le ts'epo ea sistimi.
    Likarolo tsa Bohlokoa le Tshebetso
    Transformer ea Matla ea 35MVA 115kV
    Thepa e Tsoetseng Pele le Kaho

    1. Lisebelisoa tsa Core le Coil: Core ea transformer e hahiloe ka tšepe ea silicon ea boemo bo holimo, e nang le mokhoa o tsoetseng pele oa ho kopanya step-lap ho 45° bakeng sa ho phalla ha makenete hantle. Bokaholimo bo koahetsoe ka lera le khethehileng le thibelang ho senyeha, le fokotsang tahlehelo e sa jareng mojaro le ho fokotsa maemo a lerata.

    2. Lerata le Tlase le ho Tšoarella ho Ntlafatsang: Kopano ea koili le ea mantlha e kenyelletsa likarolo tsa moralo tse ikhethileng joalo ka ho tiisa mokokotlo le tšebeliso ea lithapo tsa conductor tse fetotsoeng, ho netefatsa tlhahiso e fokolang ea lerata le botsitso ba nako e telele.

    Mochini oa ho Fetola Tap o Lahliloeng (OLTC)
    1. Transformer ea 35MVA e na le On-Load Tap Changer (OLTC) ka lehlakoreng la motlakase o phahameng, e lumellang taolo ea motlakase sebakeng sa 115kV ± 8 × 0.625%.

    2. OLTC e kenyelletsa conservator, sesupo sa boemo ba oli, Buchholz relay, le phefumoloho e itsosolosang, tsohle di tlatsetsa ts'ebetsong e sireletsehileng le e tsitsitseng ea transformer.

    Litšobotsi tsa Tšireletso le Polokeho
    1. Tšireletso ea Khase le Phapang: Transformer e na le tšireletso ea khase le li-relay tsa tšireletso ea phapang ho netefatsa ts'ebetso e sireletsehileng le ho lemoha liphoso esale pele.

    2. Tlhokomelo ea Relay: Yuniti ena e na le li-relay tsa kahare le tsa kantle tse hlahisang lialamo le ho qala ho khoptjoa ka bohona haeba ho fumanoa liphetoho tse sa tloaelehang tsa khase kapa oli.

    3. Tlhokomelo ea Boemo ba Oli: Lipontšo tsa boemo ba oli li beha leihlo boemo ba tanka ea oli, 'me lialamo lia qala haeba boemo ba oli bo oela ka ntle ho sebaka se boletsoeng, ho netefatsa tlhokomelo e ntle ea oli.
    Valve ea Phomolo ea Khatello
    Haeba khase ea ka hare e bokellana ka potlako ka lebaka la maemo a phoso, transformer e na le valve ea ho fokotsa khatello. Sistimi ena e ntša khase e feteletseng, e thibela khatello e feteletseng le ho lumella kamore ea taolo ho nka khato hang-hang ka ho qala ho tsamaea ka bohona.

    Tlhokomelo ea Mocheso
    Lipontšo tsa Mocheso oa Oli le oa ho Fetoha: Transformer e na le li-sensor ho lekola mocheso oa oli le oa ho fetoha. Haeba mocheso o feta 95°C, lets'oao la alamo le romeloa kamoreng ea ho lekola e hole. Haeba mocheso o feta 105°C, transformer e tla khoptjoa ka bo eona ho thibela ho chesa haholo le tšenyo e ka bang teng.

    Sistimi ea ho Pholisa
    Transformer e na le sistimi ea ho pholisa ea mekhahlelo e 'meli:

    Mokhahlelo oa 1: Fene ea pele ea ho pholisa e qala ho sebetsa ha mocheso o kobehang o feta 75°C.

    Mokhahlelo oa 2: Fene ea bobeli e qala ho sebetsa ha mocheso o fihla ho 80°C.
    Ha mocheso o theohela ka tlase ho 75°C, lifene lia tima ka bohona, ho netefatsa hore lia phola hantle le ho fokotsa tšebeliso ea matla.

    Mochini oa ho Phefumoloha o Itlhahisang

    Sesebediswa se seholo sa transformer le sesebediswa sa ho fetola pompo ka bobedi di na le sesebelisoa sa ho hema se itsosolosang (letshwao la Qualitrol). Sesebediswa sena se sebedisa desiccant e kentsweng kahare (silica gel) e monyang mongobo mme e iphetola ka ho futhumatsa, e thibela mongobo le moya ho kena transformer. Sena se etsa bonnete ba hore ho thibela ho kenngwa ha mocheso ho dula ho omme, ho tshehetsa botsitso ba tshebetso ya transformer nako e telele.

    Likopo
    1. Merero ea Matla a Nchafalitsoeng (Letsatsi, Moea, jj.)
    2. Kabo ea Matla a Liindasteri
    3. Ho Tsitsisa Gridi
    4. Mekhoa ea Matla e Tšepahalang Haholo
    Transformer ea Matla ea 35MVA 115kV
    Qetello

    Transformer ea Matla a Mekhahlelo e Meraro ea 35MVA 115kV ke tharollo ea sejoale-joale, e sebetsang hantle bakeng sa litsamaiso tsa sejoale-joale tsa kabo ea matla, haholo-holo mafapheng a matla a nchafatsoang. Ka thepa e tsoetseng pele, likarolo tse phahameng tsa polokeho, le moralo o bolokang matla, e fana ka bokhoni bo phahameng, ts'epo, le bophelo bo bolelele ba ts'ebeletso. Sehlahisoa sena se bontša boitlamo ba JZP Transformer ba ho fana ka litharollo tse ncha le tsa boleng ho fihlela litlhoko tsa bokamoso ba matla a tšoarellang.

    Na u se u loketse ho matlafatsa bokamoso ba matla?
    Ikopanye le rona kajeno ho ithuta haholoanyane ka moo Transformer ea Matla a Mekhahlelo e Meraro ea 35MVA 115kV e ka ntlafatsang merero ea hau ea matla a nchafatsoang le ho netefatsa kabo ea matla e tšepahalang le e sebetsang hantle.
    Qetello

    Botsa Hona Joale!

    Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.

    Leave Your Message