Transformer e kentsoeng ka mekhahlelo e meraro ea 2500kVA

Litekanyetso tsa Voltage ea Motheo: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 kapa tse ling
Litekanyetso tsa Voltage ea Bobeli: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v kapa tse ling
BOEMO BA HO THEPA HA HV: ± 2×2.5% kapa tse ling
MOFUTA OA KHOKANO: Dyn11/YNyn0 kapa tse ling
MOFUTA: Phepelo ea sekotjana/Phepelo ea mahlaseli
E NE E LE: 30/150 kV
Maemo: IEEE, CSA, DOE
Kopo: BESS, merafo ea Crypto, Indasteri, Matla a Moea le a Letsatsi, ho tjhaja EV
 Tekanyetso ea Matla: 2500 kVA, 2550 kVA, 2.5 MVA
Setifikeiti: UL, CUL, CSA, SGS

    Tlhaloso ea Sehlahisoa

    JZP Transformer ke moetsi oa litsebi oa li-transformer tse nang le lenane la UL le litifikeiti tsa maemo a motlakase ho fihlela ho 44kV, e fanang ka mefuta e felletseng ea li-transformer tse kentsoeng ka pad tse netefalitsoeng ke UL. Selemo le selemo, re romela li-transformer tsena tse likete United States le Canada. Re na le tsebo ea IEEE/ANSI, CSA, DOE, NEMA, le maemo a mang, sehlopha sa rona se netefatsa hore se latela litlhoko tse fapaneng tsa taolo. Ntle le setifikeiti sa UL, re boetse re na le litifikeiti tsa CSA, MF, CESI, le litlaleho tsa liteko tsa SGS tsa motho oa boraro. Ka boiphihlelo bo boholo ba projeke, rea utloisisa hore projeke e 'ngoe le e 'ngoe e na le litlhoko tse ikhethang. Ke ka lebaka leo re fanang ka li-transformer tse ka fetoloang, tse lumellang liphetoho ho motlakase, bokhoni, mokhoa oa khokahano, le moralo o khethehileng ho lumellana hantle le litlhoko tsa hau. Transformer e kentsoeng ka pad ea 2500 kVA e ka fetoloa hore e lumellane le litlhoko tsa projeke ea hau. Ikopanye le Daelim Transformer kajeno ho fumana leqephe la liparamente, litšoantšo le khotheishene bakeng sa transformer e kentsoeng ka pad ea 2500 kVA.
    setifikeiti01
    setifikeiti02
    setifikeiti03
    setifikeiti04
    setifikeiti05
    setifikeiti06
    setifikeiti07
    setifikeiti08
    setifikeiti09
    01020304050607

    Litlhaloso tsa Transformer ea 2500 kVA(2.5 MVA)

    Mokhahlelo Mekhahlelo e meraro Std. ANSI/IEEE Std C57 & DOE Std 2016
    Tekanyetso ea matla 2000kVA (2.5MVA) Tlhophiso Fepa e ka pele/e sa sisinyeheng
    Ho hloma Pad Mount Maqhubu 60Hz
    Motlakase oa HV 13200/6720V Sefetola-pono sa ho tobetsa Maemo a 5
    Motlakase oa LV 600/347V Bokgoni ba Mokelikeli 1600L
    KOLOI ENG? 95 kV Boima bohle 7000kG
    Koloi ea LV 30 kV Ha ho tahlehelo ea mojaro 2500W
    Sehlopha sa Vector Ka hare ho0 Ha mojaro o theohile 15000W
    Mokhoa oa ho pholisa IKHUTSE 'ME U RATE Ho se sireletsehe 5.75%
    Lisebelisoa tsa ho Tsoa Aluminium 'Mala oa Pente Munsell e tala
    Mokelikeli oa ho kenya lintho ka har'a insulation Oli ea meroho e bolang Bokgoni @ 65℃ Ho phahama ha mocheso 2500 kVA
    Sebopeho sa mantlha Kholomo ea mekhahlelo e mehlano ea mekhahlelo e meraro Moea o qobelloang (Fans) Ha ho letho

    Likarolo tsa Transformer tsa 2500 kVA
    Likarolo tsa Transformer tsa 2500 kVA
    Transformer ea ZGSL-H-2500/13.2-0.6 e na le tekanyo ea matla ea 2500 kVA (2.5 MVA). Transformer e kentsoeng ka pad ea 2500 kVA e na le tekanyo ea motlakase oa mantlha oa 13.2/7.62 kV e nang le khokahano ea Wye, ho thella ha motlakase o phahameng oa H0, le motlakase oa bobeli oa 600Y/347V Wye o nang le ho thella ha motlakase o tlase oa H0.

    Transformer ea ZGSL-H-2500/13.2-0.6 2500 kVA e na le mekhoa e mengata, 'me e loketse ho kenngoa ka tlung le kantle. Li-transformer tsena li na le mokelikeli o sireletsang oli ea meroho o senyehang 'me li boloka mocheso oa 65°C o phahama. Li tla le li-fuse tse 3 tsa ELSP le li-fuse tse 3 tsa bay-o-net bakeng sa tšireletso, hammoho le li-bushing tse 3 tsa high-voltage, li-arrester tse 3 tsa elbow (HV)), le li-bushing tse 'ne tsa low-voltage, e 'ngoe le e 'ngoe e na le masoba a 6. Sebaka sa ho kenya terminal ea low-voltage se matlafalitsoe ka poleiti ea Padmount. Ho feta moo, transformer e kentsoeng ka pad ea 2500 kVA e na le switch ea ho thiba mojaro ea maemo a mane le switch ea ho pompo ea maemo a mahlano ka lehlakoreng la high-voltage.

    ZGSL-H-2500/13.2-0.6
    ZGSL-H-2500/13.2-0.6 ke transformer e kentsweng ka pedi ya mekhahlelo e meraro ya 2500 kVA e nang le lenane la UL. Transformer e kentsweng ka pedi ya 2500 kVA e latela maemo a IEEE C57.12.34 mme e latela melao ya DOE. E hahilwe ka di-conductor tsa aluminium mme e hlophisitswe e le transformer ya mofuta wa loop-feed bakeng sa ditsamaiso tse ka pele tse sa tshwarweng. Mokgwa wa ho phodisa o sebediswang ke KNAN.

    ZGS-Z-2500(3050)/44/0.6
    ZGS-Z-2500(3050)/44/0.6 ke transformer e ikhethang ea 2500 kVA e kentsoeng ka pele e etselitsoeng ho fihlela litlhoko tse ikhethang tsa bareki ba Canada ke Daelim Transformer. Transformer ena ea 2500 kVA e kentsoeng ka tlase e latela maemo a CSA C227.4 le CAN/CSA 802.1. E na le motlakase o phahameng oa 44 kV sebopehong sa Delta le motlakase o tlase oa 600GrdY/347V.

    Transformer e na le oli ea RAPO e senyehang e le mokelikeli oa eona o thibelang mocheso 'me e etselitsoe ho phahama ha mocheso oa 55°C kapa 75°C. Tekanyo ea eona ea kVA ke 2500 kVA (2.5 MVA) ho phahama ha mocheso oa 55°C le 3050 kVA ho phahama ha mocheso oa 75°C.

    ZGS-Z-2500(3050)/44/0.6
    Se etsang hore transformer ena ea 2500 kVA e arohane ke hore motlakase oa eona o tlase o etselitsoe ho tsoa ka lehlakoreng. Ho feta moo, li-gauge, sesebelisoa sa ho fetola pompo, nameplate, valve ea ho fokotsa khatello, le valve e ka holimo ea ho tlatsa kaofela li behiloe ka ntle ho cabin e ka pele. Li-gauge tsena li na le likhokahano 'me li hokahane ka har'a lebokose la taolo ea kantle la NEMA 4. Gauge ea khatello ea vacuum e fumaneha holimo ho cabin e ka pele. Sehlahla sa motlakase o phahameng ke sehlahla se kopantsoeng sa porcelain se nang le masoba a mane, 'me lehlakore la HV le na le li-arrester tse tharo tsa lehalima, tseo e 'ngoe le e 'ngoe ea tsona e fanang ka sekoahelo sa ho thibela ho sireletsa likhoele tsa MV. Ho feta moo, li-heater tse thibelang ho kolobisoa li kentsoe ka cabin e ka pele e nang le motlakase o phahameng bakeng sa ts'ebetso e ntle ka ho fetisisa.
    2

    Transformer ea MVA ea 2.5 3 PH
    ZGSL-Z-2500/44/4.16(2.4) ke transformer e khethehileng ea 2.5 MVA e nang le mahlakore a mararo e kentsoeng ka radial pad. Tekanyetso ea eona ea mantlha ea motlakase ke 44,000 Delta V, ha motlakase oa bobeli e le 4160Y/2400 V. Transformer e hlophisitsoe ka sehlopha sa khokahano ea motlakase o phahameng le o tlase oa DYn1, 'me e latela maemo a CSA C227.4. E na le bokhoni bo tsotehang ba matla ba 99.37%, ho latela maemo a CAN/CSA-802.3. Phetoho ea transformer ho 85°C ke 5.75%, 'me e fana ka maemo a supileng a taolo ea motlakase bakeng sa lehlakore le phahameng la motlakase. Ka bokhoni ba oli bo thibelang mocheso ba 2000L le boima ba 7500 kg, ke sesebelisoa se seholo.
    2

    Transformer ea MVA ea 2.5
    Haholo-holo, e na le moralo moo likarolo tsa motlakase o phahameng le o tlase li behiloeng lehlakoreng la ho kenya, 'me karolo ea motlakase o phahameng e na le kamore ea boema-fofane ba moea e behiloeng hantle e atolohelang botlaaseng ba eona. Ho kenyelletsoa ha li-valve tsa lisebelisoa le lisebelisoa tse behiloeng ka maqiti leboteng la tanka ea mafura ea kantle ho ntlafatsa phihlello le ho netefatsa boiketlo bo eketsehileng, e leng mohlala oa moralo o hlophisitsoeng ka hloko oa transformer.
    Transformer e kentsoeng ka Pad ea 2550 kVA

    Transformer e kentsoeng ka Pad ea 2550 kVA
    ZGSL-H-2550/34.5/0.415 e emela transformer e matla e kentsoeng ka mokhoa oa loop-type pad ea mekhahlelo e meraro, e nang le tekanyo e tsotehang ea matla a 2550 kVA. E ipabola ka matla a phahameng a motlakase a 34.5 kV ha e ntse e fana ka tlhahiso e tlase ea motlakase ea 415Grd/240V. Haholo-holo, li-winding tsa eona tsa motlakase o phahameng (HV) le motlakase o tlase (LV) li entsoe ka hloko ho tsoa ho aluminium. Transformer ena e nang le tekanyo ea katleho ea 99.4% 'me e latela ka tieo maemo a nepahetseng a IEEE Std C57.12.34. Ho feta moo, ho kenyelletsoa ha eona sesebelisoa sa ho thibela mojaro sa maemo a mane ho ntlafatsa haholo ts'ebetso le mehato ea polokeho.
    Transformer ea 2550 kVA

    Transformer ea 2550 kVA
    Transformer ea 2550 kVA e sebelisa sistimi ea ho pholisa ea ONAN/ONAF, ka hona, e kenyelletsa sete ea lifene. Ha e sebetsa ka mokhoa oa ho pholisa oa ONAN, transformer e na le tekanyo ea matla ea 2550 kVA. Leha ho le joalo, mokhoa oa ho pholisa oa ONAF o ka sebetsana le tekanyo e phahameng ea matla ea 3300 kVA. Habohlokoa ke hore transformer e na le sekala sa mocheso oa oli se nang le likhokahano tsa alamo 'me e hokahantsoe le khabinete e nyane ea taolo ea tšepe e sa hloekang ea 304. Sebopeho sena se lumella ho beha leihlo hole boemo ba ts'ebetso ea transformer.

    Letoto la ZGSL-H-2550/34.5/0.415 le na le kakaretso ea liyuniti tse 'ne, tse entsoeng ka ho khetheha le ho etsoa bakeng sa bareki ba Amerika, 'me li thathamisitsoe ho UL ho fihlela maemo a thata a polokeho le boleng.

    ZGSL-H-2550/12.47/0.415
    Letoto la ZGSL-H-2550/12.47/0.415 le na le sehlopha sa di-transformer tsa 2550 kVA tse hlahisitsweng ke JZP Transformer bakeng sa bareki ba Amerika. Di-transformer tsena ke tsa mofuta o kentsweng hodima pad mme di na le tlhophiso ya ho fepa ka loop. Ditlhaloso tsa bohlokwa tsa di-transformer tsena di kenyeletsa switch ya ho kgaola mojaro ya maemo a mane, switch ya ho pompo ya maemo a mahlano, di-gauge tse nang le tšobotsi ya ho se ame, di-fuse tse tharo tsa bay-o-net, le di-fuse tse pedi tse fokotsang motlakase.
    12

    Transformer ea 12.47 kV 2550 kVA
    Ka lehlakoreng la motlakase o tlase, ho na le bracket moleng ho fana ka tšehetso bakeng sa terminal. Mokelikeli o sireletsang o sebelisoang ke oli ea minerale ea ASTM II, o nang le bokhoni ba lilithara tse 440. Tanka e etselitsoe ho mamella khatello e phahameng ka ho fetisisa ea tanka ea 10 PSI le khatello e mpe ea tanka ea 8 PSI. Boemo ba mokelikeli bo bolokoa lisenthimithara tse 10.0 ho tloha holimo ho lesoba la letsoho ho 25℃, ka liphetoho tsa boemo ba lisenthimithara tse 0.4 ka 10℃. Tanka e etselitsoe ho tlatsa vacuum ea 7 PSI 'me e lekantsoe bakeng sa 2550 kVA ha e matlafatsoa ho li-volts tse 11,847 ka sesebelisoa sa ho fetola pompo boemong ba 124,700-volt bakeng sa motlakase oa bobeli oa 415Y/240. Li-transformer tsena ha li na maemo a ka bonoang a PCB (ka tlase ho 2 ppm) nakong ea tlhahiso, ho netefatsa polokeho ea tikoloho le ho latela melao.
    13

    Transformer ea 13.2 kV 2550 kVA
    Transformer ea 2550 kVA ke transformer e entsoeng ka ho khetheha e nang le lenane la UL, e netefatsang hore e latela melao e thata ea polokeho le boleng. Sehlopha sa khokahano bakeng sa transformer ena ke Dy1·Dd0, e fanang ka mekhoa e 'meli e fapaneng ea khokahano bakeng sa motlakase o tlase:

    Bakeng sa khokahano ea 4160V Wye, li-terminal li kenyelletsa X1B, X2B, X3B bakeng sa likhokahano tsa mekhahlelo, X1A, X2A, le X3A bakeng sa likhokahano tse sa nke lehlakore. Bakeng sa khokahano ea 2400V Delta, li-terminal ke tse latelang: C1B ho ea ho X2A, X2B ho ea ho X3A, le X3B ho ea ho X1A.
    24

    Transformer ea 24.94 kV 2550 kVA
    Li-transformer tsohle tsa 2550 kVA tse kentsoeng ka pad letotong lena li hahiloe ho fihlela maemo a IEEE C57.12.34, li netefatsa boleng le ts'ebetso ea maemo a holimo. Li na le moralo oa 'metso o kenngoang ka thoko bakeng sa khokahano ea motlakase o tlase, e lumellang ho kopanngoa ho se nang sekoli le switchgear. Ho feta moo, switch ea ho khaola mojaro bakeng sa li-transformer tsena tsa 2550 kVA e entsoe ka bohlale ka har'a kamore ea khatello e tlase ea kabine e ka pele, e fana ka maemo a mane bakeng sa ho tenyetseha. Sesebelisoa sa ho fetola pompo se fana ka maemo a mahlano, 'me gear ea ho lokisa khatello e behiloe ho 24.94±2×2.5% bakeng sa taolo e nepahetseng. Impedance ea li-transformer tsena ho 85°C ke 5.87%, e netefatsang ts'ebetso e tsitsitseng le e sebetsang hantle. Ho feta moo, Maemo a tsona a Motheo a Insulation a phahameng le a motlakase o tlase (BILs) a lekantsoe ho 125kV le 30kV, ka ho latellana, ho netefatsa ts'ebetso e matla ea insulation.

    Botsa Hona Joale!

    Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.

    Leave Your Message