Leave Your Message

Transformer e kentsoeng ka Pad ea mekhahlelo e 3 ea 225 kVA 34.5kV

Litekanyetso tsa Voltage ea Motheo: 34.5kV
Litekanyetso tsa Voltage ea Bobeli: 600/347V
MOFUTA OA KHOKANO: Dyn1
MOFUTA: Pad e kentsoe
Maemo: CSA C227.4
Kopo: Mekhoa ea kabo ea indasteri
Tekanyetso ea Matla: 225kVA
Setifikeiti: CUL
Mokhoa oa ho Pholisa: IKHUTSE 'ME U RATE

    Tlhaloso ea Sehlahisoa

    JZP Transformer e motlotlo ho hlahisa transformer ea 225 kVA 34.5kV ea mekhahlelo e 3 e kentsoeng ka pad, e etselitsoeng ka ho khetheha litsamaiso tsa kabo ea indasteri. E entsoe ka maemo a holimo, e netefatsa phepelo e tsitsitseng ea motlakase bakeng sa lits'ebetso tse fapaneng tsa indasteri.
    setifikeiti01
    setifikeiti02
    setifikeiti03
    setifikeiti04
    setifikeiti05
    setifikeiti06
    setifikeiti07
    setifikeiti08
    setifikeiti09
    01020304050607
    PHETOHO E KENYELENG MOKHATLO OA MEKHATLO E MARARO

    Litlhaloso tsa Tekheniki tsa Transformer ea 225 kVA 34.5kV

    Matla a Lekantsoeng 225 kVA
    Tekanyetso ea Voltage ea mantlha 34500DELTA
    MOTLAKASE OA BOBELI 600GrdY/347
    MAKHETLO 60Hz
    Sehlopha sa Vector Dyn1
    LINTHO TSE PHETHANG Aluminium
    Tahlehelo ea Mojaro ≤2350W
    HA HO TAHLEHELO EA MOROALO ≤650W
    MOTLAKASE OA IMPEDANCE 5.75%
    BOPHAHAMO ≤1,500m
    'MALA ANSI 70 Bohlooho bo bobebe
    Boima ba oli ea ho itšireletsa 1,040 L
    BOIMA BOHLE 2,300 kg
     

    225 kVA 34.5kV Lisebelisoa tsa Transformer

    HO PHAHAMISA LETLALO ELSP FUSE
    LENYAKO LE HLOHILENG FUSE EA BAYONET
    BRACKET EA SETEI SA HO PAKA PHETOHO EA TOBETSA
    SEKOAHELO SA TANKANE Tekanyo ea Boemo ba Oli
    LV BUSHING (MEKOTA E METSOAKO E 4) VALVE EA PHOMOLLO EA KHATELLO
    SESEBEDISWA SA PHOMOLLO EA KGATELO Tekanyo ea Khatello ea Vacuum
    BAR EA KOPORO EA HV E SILOENG SEBOKO SA THEMINALI
    SESUPA SA MOCHESO MOKHOA OA LENYAKO
    HV BUSHING SILIBA (35kV) Koporo ea Lesela la ho Sila
    MOKHOA OA BAR OA KOPORO O SILOENG LEBITSO LA LEBITSO
    SWITCH EA HO THUTHA MOROALO MAEMO A MABELI LIPADI TSA TŠEPE E FATLHILENG
    VALVE EA TŠOAETSO EA 1" E NANG LE SAMPLER EA 3/8" Fensetere ea IR
    KHOKANYO EA HO KHATISA EA VALVE EA HOlimo ea 1" LEBOKOSE LA TERMINAL

    Likarolo tsa Bohlokoa
    Fensetere ea IR (Fensetere ea Infrared)
    Transformer ka 'ngoe e na le Lifensetere tsa IR likarolong tse nang le motlakase o phahameng le o tlase, e leng se lumellang basebetsi ho etsa li-infrared thermal scan ntle le ho bula mamati. Moralo ona o netefatsa tlhahlobo e sireletsehileng le e sebetsang hantle, e nolofalletsang ho lemoha esale pele libaka tse ka bang teng tsa ho chesa kapa mathata a ho chesa haholo. Ka ho khetholla likotsi tse kang ho imeloa haholo, likhokahano tse hlephileng, kapa ho kopana ho fokolang, Fensetere ea IR e ntlafatsa botsitso le polokeho ea ts'ebetso ea transformer.

    Lisebelisoa tsa Tšireletso e Tsoetseng Pele
    Transformer ea 225 kVA e na le mekhoa e mengata e tsoetseng pele ea tšireletso ho netefatsa polokeho ea ts'ebetso le bophelo bo bolelele ba ts'ebeletso, ho kenyeletsoa:

    Tekanyo ea Khatello ea Vacuum: E kenyelletsa mabitso a mabeli a alamo bakeng sa ho beha leihlo khatello ka nako ea sebele, e fanang ka temoso ea pele ea mathata a ka bang teng.

    Sesebelisoa sa ho Fokotsa Khatello: Se na le mabitso a batho ba kopanang le sona, se baka lets'oao la motlakase ha khatello e sa tloaelehang e fumanoa, se tsebisa basebetsi hore ba nke khato e hlokahalang.

    Sesupo sa Boemo ba Oli: Se na le mabitso a mabeli a alamo a lemosang sistimi ea tlhokomelo ha boemo ba oli bo sa tloaeleha, e leng se nolofalletsang basebetsi ho fetola boemo ba oli kapele le ho boloka ts'ebetso e bolokehile.

    Sesupo sa Mocheso oa Oli: Se kenyeletsa likhokahano tse peli tsa alamo—e 'ngoe bakeng sa matšoao a temoso le e 'ngoe bakeng sa matšoao a ho tsamaea. Haeba mocheso oa oli o feta 70°C, sistimi e tla fana ka temoso; haeba e feta 105°C, transformer e tla khoptjoa ka bo eona, 'me sistimi ea ho beha leihlo e tla romela lets'oao ho bontša phoso.

    Moralo o Bonolo ho Basebelisi le Tlhokomelo ea Kantle
    Li-gauge tse kentsoeng ka ntle le drain & Sample Valve: Basebelisi ba ka leka oli e thibelang mocheso le ho hlahloba li-gauge ntle le ho ipeha kotsing ea li-bushing tse nang le motlakase o phahameng le motlakase o tlase, ho ntlafatsa polokeho, bokhoni le ho latela melao.

    Tšireletso ea Sesebelisoa sa ho Fokotsa Khatello: Tšireletso ena e thibela tšenyo ea kantle, ho kenngoa tšebetsong ka phoso, le tšitiso e bakoang ke mabaka a tikoloho, e netefatsa hore sesebelisoa sa ho fokotsa khatello se sebetsa hantle le ho fokotsa kotsi ea ho lutla ha khase. E boetse e thibela litšila ho kena ka har'a transformer, e boloka bohloeki le botsitso ba nako e telele.
    Likarolo tsa Bohlokoa

    Bokgoni le Boiqapelo
    Transformer ea 225 kVA e tsoang ho JZP Transformer e entsoe ka ho totobatsa botšepehi le polokeho ea nako e telele. Ka lifensetere tsa infrared, litsamaiso tse bohlale tsa ho beha leihlo, le litsamaiso tsa kantle tse bonolo ho li sebelisa, transformer ha e ntlafatse feela katleho ea ts'ebetso empa hape e ntlafatsa polokeho ea mesebetsi ea tlhokomelo. Likarolo tsena li thusa basebetsi ho lemoha le ho rarolla mathata a ka bang teng kapele, ho fokotsa nako ea ho se sebetse le ho netefatsa tlhahiso e tsoelang pele.
    Bokgoni le Boiqapelo

    Lisebelisoa tsa Transformer tsa 225 kVA
    Mekhoa ea kabo ea matla a indasteri
    Phepelo ea motlakase ea khoebo le ea bolulo
    Liteishene tsa phetoho ea matla le motlakase tse ka nchafatsoang
    Litsi tsa data le meralo ea motheo ea bohlokoa
    Mejaro ea motlakase e batloang haholo
    JZP Transformer—Ho netefatsa Matla a Tšepahalang bakeng sa Litlhoko tsa Hao
    JZP Transformer e ikemiselitse ho fana ka litharollo tsa motlakase tsa boleng bo holimo ho bareki lefatšeng ka bophara. Ka theknoloji e tsoetseng pele le taolo e matla ea boleng, re netefatsa phepelo ea motlakase e tsitsitseng le e tšepahalang bakeng sa merero e fapaneng ea indasteri le ea khoebo. Ebang ke ho kenya lisebelisoa, tlhokomelo, kapa moralo o ikhethileng, re fana ka lits'ebeletso tsa profeshenale le tšehetso.
    Lisebelisoa tsa Transformer tsa 225 kVA

    Botsa Hona Joale!

    Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.

    Leave Your Message