Leave Your Message

Transformer e kentsoeng ka palo e le 'ngoe ea mokhahlelo o le mong—25 kVA

Litekanyetso tsa Voltage ea Motheo: 19920V
Litekanyetso tsa Voltage ea Bobeli: 120/240V
BOEMO BA HO THEPA HA HV: 18924-20916V
MOFUTA OA KHOKANO: Ii0
MOFUTA: Tloaelo
E NE E LE: 150/30kV
Maemo: IEEE C57.12.20, ANSI C57.12
Kopo: Kabo

    Tlhaloso ea Sehlahisoa

    JZP e ipabola ho hlahiseng di-transformer tsa ANSI/IEEE/UL, e bontsha boitseanape bo babatsehang le bokgoni mebarakeng ya Amerika Leboya le Borwa. Ba fana ka di-transformer tse kentsweng palong ya 25 kVA, tse ka ralwang, tsa hlahiswa, le ho etswa hore e be tsa hao ho fihlela maemo a fapaneng a matjhaba. Boitlamo ba JZP ba ho etsa botle bo etsa hore e be molekane ya tshepahalang bakeng sa ditlhoko tsohle tsa di-transformer Amerika le dinaheng tse ding.
    Transformer e kentsoeng ka palo e le 'ngoe ea mokhahlelo o le mong—25 kVA0
    Transformer ea Mokhahlelo o le Mong ea 25kVA 19.92kV
    DL-25/19.92/0.24(0.12), ke transformer e entsoeng ka mokhoa o ikhethileng e kentsoeng palong ea mohato o le mong.
    Transformer ea 25 kVA e kentsoeng ka palo e le 'ngoe e sebelisa thepa ea boleng bo holimo ea aluminium e kobehang bakeng sa likarolo tsa eona tse phahameng le tse tlase tsa motlakase, e netefatsang ts'ebetso e phahameng le ts'epo. Ka boleng ba impedance ba 2%, e na le sehlopha sa Vector sa Ii0 le polarity e ka tlosoang, e ntlafatsang ts'ebetso ea eona.
    Voltage e phahameng ea transformer e nang le maemo a mahlano a fapaneng a taolo ea motlakase, e fana ka ho tenyetseha ho ikhethang, ha mefuta ea taolo ea motlakase ea 19.92kV±2×2.5% e netefatsa botsitso bo tsitsitseng esita le nakong ea ho feto-fetoha ha maemo.
    25kVA 19
    Transformer ea Mokhahlelo o le Mong ea 25kVA 7.2(12.47)kV/4.8(8.32)kV
    Transformer ea 25 kVA e kentsoeng palong e le 'ngoe e ithorisa ka moralo oa motlakase o habeli o phahameng. Sena se nolofalletsa khetho e se nang sekoli ea motlakase o phahameng ho tloha ho 7.2kV kapa 4.8 kV, e sebetsanang hantle le litlhoko tse fapaneng tsa lisebelisoa tsa mojaro, e fana ka mekhoa e mengata e sa bapisoang.
    Transformer e kenyelletsa sistimi e sebetsang hantle ea ho pholisa ea ONAN, e tlatselitsoeng ke oli ea diminerale ea 45# e se nang PCB, e netefatsang polokeho le boikarabello ba tikoloho.
    Ka ho sebelisa sehlopha se tšepahalang sa vector sa Ii6 le polarity e eketsehileng, transformer e eme e le sehlohlolo sa ts'ebetso le ts'epo. Lisebelisoa tse ka sehloohong li kenyelletsa bushing e le 'ngoe ea motlakase o phahameng, bushing tse 3 tsa motlakase o tlase, switch e le 'ngoe ea motlakase o habeli, relief e le 'ngoe ea khatello, terminal e le 'ngoe ea H2, li-strips tse 2 tsa koporo, libaka tse 3 tsa tanka, li-lug tse 2 tsa tšehetso, li-lug tse 2 tsa ho phahamisa, le li-clamp tse 6 tsa sekoahelo, tse pakang moralo oa eona o tsoetseng pele le ho sebetsa.
    25kVA 7
    Transformer ea Mokhahlelo o le Mong ea 25kVA 17.32kV
    Transformer ena e na le motlakase oa mantlha oa 17.32 kV le motlakase oa bobeli oa 230V, o entsoeng ka hloko ho fihlela litlhoko tse khethehileng tsa moreki.
    Ka koporo e kobehileng bohareng ba eona, transformer ena e tiisa ts'ebetso e phahameng le ts'epo. E sebetsa ka maqhubu a 50 Hz mme e na le sehlopha sa Vector sa Ii0 se nang le polarity e eketsehileng, e netefatsa kopanyo e se nang sekoli lits'ebetsong tse fapaneng tsa matla.
    Transformer e nang le mefuta e fapaneng ea taolo ea 17.32kV±2×2.5%, e nolofalletsang tlhahiso ea motlakase e nepahetseng le e tsitsitseng esita le tlas'a maemo a fapaneng a mojaro.
    25kVA 17

    Botsa Hona Joale!

    Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.

    Leave Your Message