Leave Your Message

Transformer ea Matla ea Mekhahlelo e 3 ea 69kV 4200kVA 5250kVA

Litekanyetso tsa Voltage ea Motheo: 110kv, 115kv, 121kv kapa tse ling
Litekanyetso tsa Voltage ea Bobeli: 11/10.5/6.6/6.3kV kapa tse ling
BOEMO BA HO THEPA HA HV: ± 8×1.25% kapa tse ling
MOFUTA OA KHOKANO: YNd11 kapa tse ling
MOFUTA: transformer e qoelitsoeng ka oli kapa transformer ea seteishene se senyenyane

    Tlhaloso ea Sehlahisoa

    Transformer ea Matla ea Mekhahlelo e 3 ea 69kV 4200kVA 5250kVA
    Li-transformer tsa motlakase tsa 110 kV 115 kV ho latela maemo a tloaelehileng
    1. GB 6451 Litlhaloso le litlhoko tsa tekheniki bakeng sa li-transformer tsa motlakase tse qoelitsoeng ka oli;
    2. Li-Transformer tsa Matla tsa IEC 60076;
    3. AS NZS 60076 Li-Transformer tsa Matla;
    4. Li-Transformer tsa Matla tsa CSAC88-16;
    5. ANSI/IEEE C57.12.00 Tekanyetso ea IEEE bakeng sa Litlhoko tse Akaretsang bakeng sa Kabo, Matla le Li-Transformer tse qoelitsoeng ka Metsing;
    6. GOST R 52719 Li-Transformer tsa Matla - Litlhaloso tse Akaretsang;
    7. EN60076 Transformer ea Matla;
    8. Litšebeletso tsa Kamora Thekiso tsa Lehae Amerika Leboea Amerika Boroa le libaka tse ling li arabela litlhoko tsa hau nakong ea lihora tse 24.
    Transformer ea 115kV
    SF11-20000/115 ke transformer ea matla ea 115 kV 20 MVA, e fanoang ke JZP Transformer. Transformer ena e latela maemo a thata a tlhahiso ea ANSI C57 Std. E na le matla a phahameng a motlakase a 115 kV le tekanyo e tlase ea motlakase ea 13.8 kV.
    JZP Transformer e tlisa boiphihlelo bo bongata le rekoto e pakiloeng mererong ea transformer ea motlakase o phahameng ka har'a 'maraka oa Amerika. Lihlopha tsa bona tsa botekgeniki le tsa thekiso li bontša kutloisiso e tebileng ea melaoana ea lehae le ho latela maemo a ANSI, IEEE, le CSA. Li-transformer tsa HV tsa Daelim Transformer li fumane lits'ebetso tse atlehileng lits'ebetsong tse fapaneng ho pholletsa le United States, Canada, Mexico, Australia, Ecuador le lichaba tse ling.
    Transformer ea 115kV
    Likarolo tsa Transformer ea 115 kV 20 MVA
    Voltage: Transformer ena e sebetsa ho 115 kV mme e na le bokgoni bo boholo ba 20 MVA.
    Mohlokomeli oa Oli: O na le mohlokomeli oa oli bakeng sa ts'ebetso e ntlafalitsoeng le bophelo bo bolelele.
    Letšoao la Sehlopha sa Vector: Transformer e latela letšoao la sehlopha sa vector sa Dyn1.
    Mekhoa ea ho Pholisa: E sebelisa sistimi e feto-fetohang ea ho pholisa, ho kenyeletsoa mekhoa ea ONAN, ONAF1, le ONAF2. Litekanyetso tsa matla lia fapana tlas'a mekhoa ena: 12 MVA bakeng sa ONAN, 16 MVA bakeng sa ONAF1, le 20 MVA e matla bakeng sa ONAF2.
    Maemo a ho Thibela ho Kena: Boemo ba ho thibela ho kenngoeng ha motlakase ka motlakase o phahameng bo behiloe ho 550 kV, ha boemo ba ho thibela ho kenngoeng ha motlakase ka motlakase o tlase e le 110 kV.
    Litekanyetso tsa Mocheso: Transformer ena e etselitsoe ho sebetsana le keketseho e phahameng ka ho fetisisa ea mocheso o kobehang oa 65℃ le keketseho e phahameng ka ho fetisisa ea mocheso oa oli oa 55℃.
    Mofetoleli oa Tap: Lehlakore la HV le na le mofetoleli oa tap oa maemo a 5 o feto-fetohang, o lumellang maemo a mahlano a taolo ea motlakase ka har'a sebaka sa ± 2×2.5%.
    Li-bushing: Li-bushing tse nang le motlakase o phahameng le o tlase li kenngoa hantle holimo.
    Li-Surge Arrestor: Bakeng sa polokeho le ts'ireletso e ntlafalitsoeng, lehlakore la motlakase o phahameng le na le li-surge arrestor tse tharo.
    Likarolo tsa Transformer ea 115 kV 20 MVA
    Transfoma ea 110kV ea 115kV
    Li-transformer tsa motlakase tsa 115kV/110kV li entsoe le ho ntlafatsoa ka ho monya le ho sebelisa mahlale a tsoetseng pele ka hare ho naha le kantle ho naha ho ntlafatsa motheo oa transformer, coil, body, load, peterole, le likarolo tse ling, tse nang le phallo e tlase ea karolo, tahlehelo e tlase, lerata le tlase, bobebe le ts'epo e phahameng. Ts'ebetso ea eona e ntle e hapile thoriso e kholo ho tsoa ho basebelisi le litsebi tse amehang. Sehlahisoa sena se na le litšobotsi tsa botsitso, moruo le tšireletso ea tikoloho, 'me se loketse lifeme tsa motlakase, liteishene tse nyane, likhoebo tse kholo tsa indasteri le tsa mineralization, jj.
    Transfoma ea 110kV ea 115kV
    Teko le Litšoaneleho
    Transformer ea 115 kV 20 MVA e feta litekong tse felletseng ho netefatsa hore e fihlela maemo a thata a behiloeng ke ANSI C57. Liteko tsena li kenyelletsa:
    Tekanyo ea ho kenya mocheso
    Tekanyo ea Karolelano ea Voltage le Sehlopha sa Vector
    Tekanyo ea Liparamente tsa ho Fetoha
    Teko ea ho Ikemela ea Voltage ea Mohloli o Arohileng oa Matla le Maqhubu
    Tekanyo ea Bokhoni ba ho Fokotsa Matla le Ntlha ea ho Hlakola ha Dielectric
    Teko ea ho Ikokobetsa ea Motlakase oa Mabone
    Teko ea ho mamella ho feta motlakase le ho qhala karolo e itseng
    Tekanyo ea Voltage ea Impedance le Tahlehelo ea Moroalo
    Tekanyo ea Teko ea ho se Tšepe ea Zero-Sequence ea Boemo ba Lerata
    Teko ea Khatello ea Setiiso Teko ea Phahamo ea Mocheso
    Tekanyo ea Kou ea Karabelo ea Phetoho ea Maqhubu a Phefumoloho
    Teko ea Tekanyo ea Tekanyo ea Polarity ea Teko ea Hona Joale ea Transformer
    Lebenkele lena la liteko le netefatsa hore transformer ea 115 kV e latela maemo a ANSI C57 mme e tšoaneleha ka botlalo, e leng se netefatsang ts'epo le ts'ebetso ea eona.
    Teko le Litšoaneleho
    Litlhaloso tsa Transformer ea Matla ea 110kV le 115kV
    110kv Transformer ea matla a ho phetholla mojaro ea mekhahlelo e meraro ea duplex
    Tekanyetso Motlakase o Kopantsoeng Ha ho Tahlehelo ea Moroalo Tahlehelo ea Mojaro Ha ho na mojaro oa hona joale Impendance ea potoloho e khuts'oane
    (kVA) HW LV
    6300 kVA 110kV ±8 6.3kv 10 36 0.8 10.5
    8000 kVA ×1.25% 6.6 kW 12 45 0.8
    10000 kVA   10.5kv 14.2 53 0.74
    12500 kVA 115kV ±8 11kv 16.8 63 0.74
    16000 kVA ×1.25%   20.2 77 0.69
    20000 kVA     24 93 0.69
    25000 kVA     28.4 110 0.64
    31500 kVA     33.8 133 0.64
    40000 kVA     40.4 156 0.58
    50000 kVA     47.8 194 0.58
    63000 kVA     56.8 234 0.52
    110kv Transformer ea matla a mapheo a mekhahlelo e meraro ea boraro holim'a phetoho ea mojaro
    Tekanyetso Motlakase o Kopantsoeng Ha ho Tahlehelo ea Moroalo Tahlehelo ea Mojaro Ha ho na mojaro oa hona joale
    (kVA) HV(kV) MV(kV) LV(kV)
    6300 kVA 110kv±8 35kv 6.3kv 12 47 0.95
    8000 kVA ×1.25% 37kv 6.6 kW 14.4 56 0.95
    10 MVA   38.5kv 10.5kv 17.1 66 0.89
    12.5 MVA 115kv±8   11kv 20.2 78 0.89
    16MVA ×1.25%     24.2 95 0.84
    20MVA       28.6 112 0.84
    25MVA       33.8 133 0.78
    31.5MVA       40.2 157 0.78
    40MVA       48.2 189 0.73
    50MVA       56.9 225 0.73
    63MVA       67.7 270 0.67

    Botsa Hona Joale!

    Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.

    Leave Your Message