Leave Your Message

Li-Transformer tsa Mofuta o Omileng tse Bokgoni bo Phahameng

Transformer ea mofuta o omileng ke sesebelisoa sa motlakase sa sejoale-joale se entsoeng ka mokhoa o sireletsehileng, o tšepahalang le o sebetsang hantle lits'ebetsong tse fapaneng. Ho fapana le li-transformer tse qoelitsoeng ka oli, li-unit tsa mofuta o omileng li sebelisa ho thibela matla a tiileng kapa a khase (mohlala, epoxy resin, cast resin, kapa khase ea SF6) ho fapana le oli ea diminerale, e leng se felisang likotsi tsa mollo le tšilafalo ea tikoloho. Li loketse ho kenngoa ka tlung, libakeng tsa litoropo le libakeng tse bonolo, li-transformer tsena li kopanya botsitso, tlhokomelo e tlase le ts'ebetso e phahameng.

    Litšobotsi tsa Bohlokoa le Melemo

    Moralo o sa Cheseng le o Sireletsang Tikoloho​
    Ka lebaka la ho se be le oli e tukang, di-transformer tsa mofuta o ommeng di fihlela maemo a thata a polokeho ya mollo (IEC 61558) mme di loketse dipetlele, ditsi tsa data le meaho ya bodulo. Thepa e ka sebediswang hape mme oli ha e dutle di netefatsa ho latela melao ya tikoloho.
    .Bokgoni bo Phahameng le Poloko ea Matla​​
    Lisebelisoa tse tsoetseng pele tsa mantlha (amorphous alloy kapa silicon steel) le meralo e ntlafalitsoeng ea ho kobeha li fokotsa tahlehelo ea matla ka ho fihla ho 30%, li fihlella maemo a katleho ≥98% (e netefalitsoeng ke IEC 61378). E loketse ts'ebetso e tsoelang pele ka tlhahiso e fokolang ea mocheso.
    .Tlhokomelo e Tlase le Bophelo bo Bolelele​​
    Mekhoa e tiileng ea ho thibela mocheso e hanela mongobo, lerōle le litšila tsa lik'hemik'hale, e fokotsang litlhoko tsa tlhokomelo. Kaho e tiileng e mamella maemo a thata, e lelefatsa bophelo ba tšebeletso libakeng tsa indasteri kapa tsa lebopong.
    .E nyane le e Bolokang Sebaka​​
    Meralo ea modular le mehato e menyenyane ea maoto li nolofatsa ho kenngoa liteisheneng tse nyane tsa litoropo, mehahong ea khoebo, kapa libakeng tsa eneji e nchafatsoang. E fumaneha ka li-voltage ho tloha ho 380V ho isa ho 36kV le bokhoni bo fihlang ho 5 MVA.
    .Tlhokomelo e Bohlale le Polokeho​​
    Li-sensor tsa IoT tse ikhethileng li hlahloba mocheso, motlakase, le mojaro ka nako ea sebele, li nolofalletsa tlhokomelo e boletsoeng esale pele. Mekhoa ea tšireletso e hahiloeng kahare (mohlala, li-relay tsa mocheso, lialamo tsa Buchholz) e thibela liphoso le ho netefatsa ts'ebetso e sireletsehileng.
    Phetoho e Phahameng ea Phetoho e Iketselitsoeng ka Oli ea Cooper 10001Phetoho e Phahameng ea Phetoho e Ileng ea Koenngoa ka Oli ea Cooper 10002Phetoho e Phahameng ea Oli ea Cooper e Immeng ka Oli 10003
    Li-Transformer tsa Mofuta o Omileng tse Bokgoni bo Holimo
    • Li-Transformer tsa Mofuta o Omileng tse Sebetsang Haholo (1)
    • Li-Transformer tsa Mofuta o Omileng tse Bokgoni bo Holimo (2)
    • Li-Transformer tsa Mofuta o Omileng tse Bokgoni bo Holimo (3)
    • Li-Transformer tsa Mofuta o Omileng tse Bokgoni bo Holimo (4)
    • Li-Transformer tsa Mofuta o Omileng tse Sebetsang Haholo (5)
    Transformer e qoelitsoeng ka oli ea Cooper01

    Likopo

    Meralo ea Motheo ea Litoropo: Kabo e sireletsehileng ea motlakase libakeng tse nang le batho ba bangata, mabenkeleng a maholo le litsamaisong tsa terene e tsamaeang ka tlas'a lefatše.
    Tšebeliso ea indasteri: Phepelo e tsitsitseng bakeng sa lifeme tsa tlhahiso, mesebetsi ea merafo le liindasteri tsa lik'hemik'hale.
    .Matla a Nchafatsoang: Kopanyo le mapolasi a letsatsi/moya bakeng sa khokahano e sebetsang hantle ea gridi.
    .Mehaho ea Khoebo: Litsamaiso tsa HVAC, lifti le marangrang a mabone.

    Litlhaloso tsa Tekheniki

    Mefuta ea Motlakase: 380V ho isa ho 36kV (motlakase o mahareng).
    .Bokgoni: 50 kVA ho isa ho 5,000 kVA.
    .Mefuta ea ho Pholisa: Moea oa Tlhaho (AN) kapa Moea o Lebohang (AF).
    .Sehlopha sa ho kenya mocheso: Sehlopha sa H (180°C) bakeng sa ho mamella mocheso o phahameng.
    .Makgetlo: 50Hz/60Hz.

    Netefaletso ea boleng

    Teko e matla e kenyelletsa motlakase o susumetsang, tahlehelo ea mojaro, le li-simulation tsa ho phahama ha mocheso.
    E netefalitsoe ke IEC, IEEE, ISO 9001 (boleng), le ISO 14001 (tikoloho).

    Hobaneng re ka re Khetha?

    Lilemo tse 30+ tsa Botsebi: Meralo e pakiloeng bakeng sa mocheso o feteletseng, mongobo le libaka tse nang le litšisinyeho tsa lefatše.
    .Tšehetso ea Lefatše ka Bophara: Lihlopha tsa boenjiniere tsa lehae le thuso ea botekgeniki ea 24/7.
    .Litharollo tse Theko e Tlase: Meralo e ka atolosoang ka dikgetho tse tenyetsehang tsa ditjhelete.

    Litharollo tse Ikhethileng

    Mehlala e Hanelang Mollo le e Sireletsang ho phatloha: Bakeng sa libaka tsa oli/khase kapa libaka tse kotsi.
    .Meralo e Sireletsang Tikoloho: Lerata le tlase (
    .Mekhoa ea Motsoako: E kopantsoe le polokelo ea matla bakeng sa lits'ebetso tse bohlale tsa gridi.
    Transformer e qoelitsoeng ka oli ea Cooper02Transformer e qoelitsoeng ka oli ea Cooper03Transformer e qoelitsoeng ka oli ea Cooper04Transformer e qoelitsoeng ka oli ea Cooper05

    Melemo ea sehlahisoa

    1. Lisebelisoa tsa Bohlokoa le Moralo oa ho Fetola
    Lisebelisoa tsa Bohlokoa
    Li-cores tsa Alloy tsa Amorphous:
    Tahlehelo ea tšepe e tlase haholo (70–80% e tlase ho feta tšepe ea silicon ea setso), e fokotsang tšenyo ea matla le litšenyehelo tsa ts'ebetso.
    Ho kenella ha metsi ka bongata le ho thibela motlakase ho batlang ho se na letho ho fokotsa lerata le ho thothomela, e leng se loketseng libaka tsa bolulo le tsa khoebo.
    Tšepe ea Silicon e Metsi a Koahetsoeng ke Lijo-thollo (CRGO):
    Li-lamination tse khaotsoeng ka laser kapa tse nang le mehato li fokotsa tahlehelo ea hona joale ea eddy, li fihlella maemo a katleho ho fihlela ho 98% (litekanyetso tsa IEC 60076).
    Tekanyo e ntlafetseng ya dijo-thollo e ntlafatsa bongata ba flux ya makenete bakeng sa ditshebediso tsa motlakase o phahameng (ho fihlela ho 33kV).
    Moralo oa ho Fetoha
    Li-winding tsa foil tse nang le Resin Impregnation:
    Mabili a koporo kapa a aluminium foil a fokotsa phallo ea ho lutla le matla a potoloho e khuts'oane. Ho koaheloa ha resin ea epoxy ho eketsa matla a mechini le ho tsamaisa mocheso.
    Mealo e kopaneng e fokotsa khatello ea motlakase oa ho potoloha, e ntlafatsa ho mamella potoloho e khuts'oane (ho fihlela liphosong tse sa lekanang tsa 50 kA).
    Li-winding tsa terata tsa Litz tse nang le mekhahlelo:
    Terata ea Litz ea likhoele tse ngata e fokotsa litlamorao tsa letlalo le bohaufi, e fokotsa khanyetso ea AC lits'ebetsong tse sebelisoang khafetsa (mohlala, li-converter tsa HVDC).
    Ho Kenngwa ha Kankere le Kgatelelo ya Vacuum (VPI):
    Likhoele li tšeloa ka li-resin tsa epoxy kapa polyester tse nang le mocheso o phahameng, ho netefatsa ho hanyetsa mongobo le matla a dielectric ho fihlela ho 200 kV BIL.
    .2. Mekhoa ea ho kenya mocheso
    Ho lahla Resin ea Epoxy:
    Sehatsetsi se tiileng se nang le li-resin tsa epoxy tsa Sehlopha sa H se fana ka khanyetso ea mollo (se netefalitsoeng ke UL94 V-0) 'me se mamella potoloho ea mocheso (−40°C ho isa ho +155°C).
    Ho hanyetsa ho ntsha metsi ka karolo e itseng ho hoholo, ho loketse ditikoloho tse silafetseng kapa tse mongobo.
    Motsoako oa Pampiri ea Nomex:
    Ho kwahela ha thepa ho thehilweng ho faeba ya Aramid ho fana ka botsitso bo phahameng ba mocheso (ho fihlela ho 220°C) le matla a dielectric, hammoho le thepa ya ho thibela malakabe.
    ​Sesebelisoa se Ntlafalitsoeng sa Nano:
    Metswako ya epoxy e tletseng silika e ntlafatsa bophelo ba ho ntsha metsi ka karolo e itseng ka 40%, e leng se eketsang bophelo ba tshebeletso maemong a thata.
    .3. Tsamaiso ea Thermal​
    Ho Pholisa Moea ka Tlhaho (AN):
    Ho pholisa ho sa sebetseng ka li-radiator tse nang le mapheo kapa li-heat sinks bakeng sa ts'ebetso e tsoelang pele meroalong e lekantsoeng (mohlala, li-unit tsa 500kVA–1.5MVA).
    Ho Pholisa Moea ka Matla (AF):
    Lifene tse laoloang ke mocheso li ntlafatsa ho qhalana ha mocheso, li nolofalletsa bokhoni ba ho jara boima ba 120–150% bakeng sa maemo a tšohanyetso.
    Tlhokomelo e Bohlale ea Thermal:
    Li-sensor tsa mocheso tse kentsoeng le litsamaiso tsa IoT li baka lialamo kapa liphetoho tsa ho pholisa ho thibela ho chesa haholo le ho senyeha ha insulation.
    .4. Moralo le Tšireletso ea Meaho
    Moralo oa Modular le o Monyenyane
    Li-enclosure tsa Hermetic:
    Li-enclosure tse nang le tekanyo ea IP66/IP67 tse nang le li-gasket tsa EPDM li sireletsa khahlanong le lerōle, metsi le ho kenella ha litoeba, tse loketseng libaka tsa kantle kapa tsa indasteri.
    Liaparo tse Khahlanong le ho Senyeha:
    Matlo a tšepe a galvanized kapa a aluminium a nang le masela a polyurethane/phofo a hanela ho senyeha ha mahlaseli a kotsi a UV le ho pepesehela letsoai la lebopong.
    Lisebelisoa tse sa Cheseng:
    Mekhoa ea ho kenya mocheso e sa cheseng le ea resin e itimang e fihlela litekanyetso tsa polokeho ea mollo tsa IEC 60335.
    Likarolo tsa Polokeho
    Sistimi ea Phokotso ea Khatello:
    Mekero ea moea e iketsang e fokotsang khatello e thibela ho hloleha ho phatloha nakong ea liphoso tsa ka hare.
    Tšireletso ea ho phahama ha metsi:
    Li-arrester tse kopantsoeng tsa tšepe (MOA) li thibela liphetoho tse bakoang ke lehalima (≥2.5 kA impulses).
    Thibelo ea ho sila le ho tšoloha:
    Mekhoa e matlafalitsoeng ea ho thella le meralo e koetsoeng e felisa likotsi tsa ho lutla ha oli, e leng se etsang hore ho se be le tšilafalo tikolohong.
    .5. Tshebetso e Tsoetseng Pele​
    Sistimi ea Tlhokomelo ea Maemo (CMS):
    Li-sensor tse kentsoeng li latela mocheso o kobehileng, ho tsoa ha motlakase ka karolo e itseng, le maemo a mojaro, e leng se nolofalletsang tlhokomelo e boletsoeng esale pele ka li-platform tsa SCADA kapa IoT.
    Kopanyo ea Smart Grid:
    Puisano e nolofalitsoeng ke IoT e tšehetsa tlhokomelo e hole, ho leka-lekanya mojaro, le likarabo tsa gridi ea ho ipholisa.
    Mekhoa e Mecha e Sireletsang Tikoloho:
    Li-resin tse sireletsang mocheso tse thehiloeng ho bio le likarolo tsa polymer tse ka sebelisoang hape li lumellana le lipheo tsa botsitso (mohlala, ho latela melao ea RoHS le REACH).
    ​Litšebeliso tsa Bohlokoa le Mekhoa ea Nakong e Tlang​
    Kabo ea Litoropo le Khoebo:
    Metse ea motlakase ea li-unit tse nang le bongata bo phahameng (500kVA–2 MVA), litsi tsa data, le liteishene tsa ho tjhaja motlakase oa EV.
    Matla a Indasteri le a Nchafatsoang:
    E loketse liteishene tse nyane tsa polasi ea letsatsi/moea, libaka tsa merafo, le libaka tse kotsi (Sebaka sa 2/22).
    Tsoelo-pele ea Nakong e Tlang:
    Li-Transformer tsa Boemo bo Tiileng (SSTs): E nolofalletsa phetoho ea DC-DC le ho tenyetseha ha gridi bakeng sa litsamaiso tsa eneji tse arotsoeng ka thoko.
    ​Li-Nanocomposites tse Ipholisang: Thepa e tsoetseng pele e ipholisa mocheso ka bo eona tlas'a maemo a phoso.
    Kakaretso
    Li-Transformer tsa Mofuta o Omileng li ipabola ka li-core tse sa lahleheng haholo, ho mamella ho kenella ha mocheso ka matla, le taolo e bohlale ea mocheso. Polokeho ea tsona mollong, ts'ebetso e sa hlokeng tlhokomelo, le meralo e sireletsang tikoloho li etsa hore li be tsa bohlokoa bakeng sa li-grid tsa litoropo le tsa indasteri tsa sejoale-joale, ha boqapi bo kang theknoloji ea 'muso o tiileng' le kopanyo ea IoT li tsamaisa bohlale ba grid le botsitso.
    Transformer e qoelitsoeng ka oli ea Cooper06Transformer e qoelitsoeng ka oli ea Cooper07Transformer e qoelitsoeng ka oli ea Cooper08Transformer e qoelitsoeng ka oli ea Cooper09

    Botsa Hona Joale!

    Bakeng sa lipotso mabapi le lihlahisoa tsa rona kapa lethathamo la litheko, ka kopo re siele lengolo-tsoibila la hau 'me re tla ikopanya le rona nakong ea lihora tse 24.

    Leave Your Message