+86 18068001229 Ho Utloisisa Likhokahano tsa Transformer tsa Mokhahlelo o le Mong: Tataiso e Felletseng ea JZP
Transformer ea Mokhahlelo o le Mongs ke likarolo tsa motheo litsamaisong tsa motlakase, tse sebelisoang haholo bakeng sa taolo ea motlakase, karohano le kabo ea motlakase. Ho JZP, re rala le ho etsa li-transformer tsa mohato o le mong tse sebetsang hantle tse etselitsoeng lits'ebetso tse fapaneng tsa indasteri le tsa khoebo. Sengoloa sena se hlahloba melao-motheo, mekhoa le mekhoa e metle ea ho hokahanya li-transformer tsa mohato o le mong, ho netefatsa ts'ebetso e sireletsehileng le e sebetsang hantle.
- Sebopeho sa Motheo sa Transformer ea Mokhahlelo o le Mong
Transformer ea mohato o le mong e na le mapheo a mabeli a insulated (a mantlha le a bobeli) a leketlileng ho potoloha motheo o arolelanoang oa makenete. Mapheo a mantlha a amohela motlakase oa AC, a hlahisang phallo ea makenete e bakang motlakase ho mapheo a bobeli ka induction ea motlakase.
Litlhophiso tsa lithapo: Laola hore na motlakase le maqhubu a fetoha joang.
- Mekhoa e Tloaelehileng ea Khokahano
- Kgokelo ya Mokgahlelo o le Mong ho ya ho Mokgahlelo o le Mong
Ena ke tlhophiso e bonolo ka ho fetisisa, e sebelisoang bakeng sa ho eketsa kapa ho theola motlakase lits'ebetsong tsa bolulo kapa tse nyane. Mohlala:
Ho kobeha ha motlakase ho ka sehloohong: Ho hokahantsoe le phepelo ea AC ea 240V.
Ho kobeha ha bobeli: E fana ka 120V AC bakeng sa lisebelisoa tsa lapeng.
Lintlha tsa bohlokoa:
Netefatsa ho lumellana ha polarity ho qoba lipotoloho tse kgutshwane.
Sebelisa insulation e loketseng bakeng sa litekanyetso tsa motlakase.
- Kgokelo ya Mokhahlelo o le Mong ho ya ho Mekhahlelo e Meraro
Ho fana ka motlakase oa mekhahlelo e meraro, li-transformer tse tharo tsa mohato o le mong li ka hokahanngoa ka litlhophiso tsa Wye kapa Delta:
Khokahano ea Wye-Wye:
Mabili a mantlha le a bobeli a bopa sebopeho sa naleli, 'me lebili le leng le le leng le hokahantsoe le ntlha e sa nke lehlakore.
Melemo: E leka-lekanya di-voltage tlasa meroalo e sa leka-lekanang; e loketse ditsamaiso tsa 120/208V.
Khokahano ea Delta-Wye:
Mabili a mantlha a Delta, a bobeli a Wye.
Ditshebediso: Ditsamaiso tsa indasteri tse hlokang matla a mangata le karohano ya mekhahlelo.
- Teko le Polokeho ea Polarity
Polarity e fosahetseng e ka lebisa tšenyo ea lisebelisoa kapa ho hloleha ha sistimi. JZP e khothaletsa:
Mongolo wa matheba: Hlalosa di-terminal tsa transformer (mohlala, H1 le X1) ho netefatsa ho otloloha ha mokgahlelo hantle.
Teko ea potoloho e bulehileng: Lekanya motlakase ho pholletsa le li-terminal tse bulehileng ho netefatsa polarity (mohlala, 208V e lebelletsoe bakeng sa li-winding tsa 120V ho Wye).
Ho thella: Hokela ntlha e sa nke lehlakore le lefatshe bakeng sa botsitso le tshireletso ya ho phahama ha metsi.
- Litšebeliso tse sebetsang
Tšebeliso ea matlo: Li-transformer tsa mohato o le mong li fana ka motlakase matlong ka litsamaiso tsa 120V/240V.
Mehaho ea khoebo: Libanka tse hokahantsoeng ke Wye li fana ka 120/208V bakeng sa HVAC le mabone.
Matla a ka tsosolosoang: Arola li-inverter tsa letsatsi ho tsoa ho gridi ho thibela karabelo.
- Melemo ea Tekheniki ea JZP
Ho JZP, di-transformer tsa rona di entswe bakeng sa:
Bokgoni: Tahlehelo e tlase ya mantlha le ho hanyetsa koporo.
Ho tšoarella: Ho sireletsa mocheso ka matla bakeng sa libaka tse mongobo/mocheso o phahameng.
Ho latela Melao: Ho latela maemo a IEC le IEEE.
Qetello
Kgokelo e nepahetseng ya di-transformer tsa mohato o le mong e bohlokwa bakeng sa botshepehi le polokeho ya sistimi. Hore na o hlophisa yuniti e ikemetseng kapa banka ya di-transformer tse ngata, ho utlwisisa dikamano tsa motlakase, polarity, le melaomotheo ya ho thella ho netefatsa tshebetso e ntle ka ho fetisisa. Bakeng sa ditharollo tse ikgethileng, buisana le sehlopha sa boenjiniere sa JZP ho kgetha di-transformer tse tsamaellanang le ditlhoko tsa hao tsa motlakase, matla le tshebediso.