+86 18068001229 "Mehato e Mehlano ea Thibelo" Liteisheneng tse Nyenyane: Tataiso e Felletseng
Sistimi ea "Lithibelo tse Hlano" liteisheneng tse nyenyane ke mokhoa oa bohlokoa oa polokeho o etselitsoeng ho thibela liphoso tsa ts'ebetso le ho netefatsa ts'ebetso e sireletsehileng le e tšepahalang ea lisebelisoa tsa motlakase tse nang le motlakase o phahameng. Ha li-grid tsa motlakase li ntse li rarahana le ho feta, litsamaiso tsena li bapala karolo ea bohlokoa ho fokotseng likotsi tse kang likotsi tsa motlakase, tšenyo ea lisebelisoa le ho tima ha motlakase. Sengoloa sena se hlahloba tlhaloso, likarolo, melao-motheo ea ts'ebetso le ts'ebeliso e sebetsang ea Lithibelo tse Hlano liteisheneng tse nyane tsa sejoale-joale.
- Tlhaloso ea Lithibelo tse Hlano
Lithibelo tse Hlano li bua ka litšireletso tse hlano tsa bohlokoa tse kopantsoeng le lisebelisoa tsa seteishene sa ho fokotsa liphoso tsa batho nakong ea ts'ebetso. Tsena li kenyelletsa:
Thibelo ea Tšebeliso e Mpe ea Li-circuit Breaker: Ho netefatsa hore li-circuit breaker ha li buloe kapa ho koaloa ka phoso, e leng se ka sitisang phallo ea motlakase kapa sa senya lisebelisoa.
Thibelo ea Ts'ebetso ea Phetoho ea ho Ikarola e Jarang Mojaro: Ho thibela ho buloa kapa ho koaloa ha li-switch tsa ho ikarola ha li ntse li jarisoa, e leng boemo bo ka bakang ho hloleha ha li-arcing kapa lisebelisoa.
Thibelo ea ho Kenya Terata e Tletseng Mobu: Ho thibela boiteko ba ho hokela lithapo tse thellang mobu kapa liswichi ho lipotoloho tse phelang, e leng se behang kotsing lipotoloho tse kgutshwane tse matla.
Thibelo ea Li-circuit Breaker tse Koalang ka Lithapo tse Theolang: Ho netefatsa hore li-circuit breaker li ke ke tsa koaloa haeba lithapo tse thellang kapa li-switch li ntse li hoketsoe, ho qoba ho ntša metsi ka tsela e kotsi.
Thibelo ea ho Kena ka Liphaposing tse Phelang ka Tsela e sa Lumelloang: Ho thibela phihlello libakeng tsa motlakase tse phelang ntle le haeba melaoana eohle ea polokeho e tiisitsoe.
Mehato ena e qobelloa ka ho kenella ha mechini, taolo ea logic ea motlakase, le mekhoa ea ts'ebetso ho felisa ho se hlaka maemong a kotsi e kholo.
- Melao-motheo ea Ts'ebetso ea Lithibelo tse Hlano
Sistimi ena e sebetsa ka motsoako oa liteko tsa pele ho ts'ebetso tse thehiloeng ho ketsiso le netefatso ea logic ea nako ea sebele:
Pele ho Tshebetso ya Ketsiso: Pele ho ts'ebetso efe kapa efe ya mmele, botekgeniki ba etsisa tatellano khomphutheng ya "Five Prevention Host". Sistimi e bapisa mehato e rerilweng le melao ya yona ya logic e hlophisitsweng esale pele le boemo ba hajwale ba disebediswa (mohlala, maemo a sekgahla sa potoloho, boemo ba terata ya ho thella).
Ho Notlela ka Mokhoa o Lokileng: Haeba ts'ebetso e tlōla melao ea polokeho (mohlala, ho leka ho bula sesebelisoa sa ho thiba potoloho se phelang), sistimi e thibela ketso mme e lemosa opereishene. Litaelo tse nepahetseng feela li fetisetsoa ho linotlolo tsa 'mele (mohlala, linotlolo tse nang le khoutu kapa li-interlock tsa mechini) ho lumella ho etsoa.
Tlhokomelo ea Nako ea Sebele: Li-sensor le li-contact tse thusang ho data ea boemo ba sesebelisoa ho sistimi, ho netefatsa hore ho na le ho lumellana pakeng tsa sebopeho sa taolo le maemo a 'nete. Litsamaiso tse tsoetseng pele li sebelisa matšoao a ho kopana habeli le li-algorithms tsa ho hokahanya ka boiketsetso ho fokotsa liphetho tse fosahetseng.
- Liphephetso le Litharollo
Leha lithibelo tse hlano li le bohlokoa haholo, liphephetso li ntse li le teng:
Ho Nepahala ha Letšoao: Maqhama a thusang a nang le liphoso kapa matšoao a nakoana a ka khelosa sistimi. Mohlala, boemo ba sehahi sa potoloho bo tlalehiloeng hampe bo ka qoba liteko tsa polokeho.
Tharollo: Kenya di-sensor tse nang le kgokelo e pedi le matshwao a boemo ba sebele. Haeba ho hlaha diphapang, sistimi e qala dialamo mme e notlela tshebetso ho fihlela netefatso ya letsoho.
Ho rarahana ha Lintlafatso: Ho lokisa liteishene tse nyane tsa khale ka litsamaiso tsa sejoale-joale tsa Thibelo ea Metsotso e Mehlano ho hloka ho rala bocha li-interlock le melao ea logic.
Tharollo: Meralo ea Modular le Seteishene se seng se entsoeng esale peles (mohlala, liteishene tse nyane tsa 35kV) li kopanya likarolo tse hlano tsa Thibelo nakong ea kaho, li nolofatsa ntlafatso.
- Litšebeliso tse sebetsang
Thuto ea Nyeoe ea 1: Xinjiang, Chaena, sistimi ea "Thibelo e Hlano" seteisheneng se senyenyane sa 110kV Luokou e ile ea lokisoa ka botlalo ka 2023. Litaba tse fetang 1,891 li ile tsa rarolloa, ho kenyeletsoa le linotlolo tse siiloeng ke nako le liphoso tsa logic, ho netefatsa polokeho ea ts'ebetso ea 100% nakong ea tlhoko e phahameng ea mariha.
Thuto ea Nyeoe ea 2: Liteishene tse nyenyane tse entsoeng esale pele libakeng tsa litoropo (mohlala, mehahong ea bolulo) li kenyelletsa likarolo tse hlano tsa Thibelo joalo ka liswichi tsa SF6 tsa ho thibela ho chesa le litsamaiso tsa taolo ea mocheso ho thibela ho chesa haholo le phihlello e sa lumelloang.
- Mekhoa ea Nakong e Tlang
Kopanyo ea AI: Li-algorithms tse tsoetseng pele, joalo ka ntlafatso ea likolone tsa bohloa, li ntse li lekoa ho nolofatsa mokhoa o thehiloeng melaong le ho fokotsa ho kenella ha batho ho hlahiseng liprothokholo tse hlano tsa Thibelo.
Tlhokomelo e Nolofalitsoeng ke IoT: Li-sensor tse bohlale le li-platform tse thehiloeng marung li tla nolofalletsa ho arolelana data ka nako ea sebele ho pholletsa le liteishene tse nyane, ho ntlafatsa tlhokomelo ea ho bolela esale pele le ho lemoha lintho tse sa tloaelehang.
Qetello
Sistimi ea Thibelo tse Hlano ke motheo oa polokeho ea seteishene se senyenyane, e kopanyang ho tiea ha mechini le monahano o bohlale ho thibela liphoso tse kotsi. Ha li-grid li ntse li fetoha ho ea ho li-grid tse bohlale le kopanyo ea matla a nchafatsoang, tsoelo-pele ho AI le moralo oa modular li tla matlafatsa karolo ea eona ho bolokeng botsitso ba grid. Bakeng sa lits'ebeletso tsa motlakase, ho tsetela meralong ea motheo e matla ea Thibelo ea Tse Hlano ha se tlhoko ea taolo feela empa ke tlhoko ea leano ea ho sireletsa meralo ea motheo le polokeho ea sechaba.