+86 18068001229 Papiso ea Tekheniki: Transformer ea ho Itšehla khahlanong le Transformer e Tloaelehileng
- Lipakane tsa Bohlokoa tsa Mosebetsi
Li-Transformer tse Tloaelehileng
Haholo-holo e etselitsoe phetoho ea motlakase (ho nyoloha/ho theoha), ka karolelano e sa lekanang ea ho reteleha lipakeng tsa mapheo a mantlha/a bobeli. Morero oa bona oa mantlha ke phetoho ea motlakase oa AC ho fihlela litlhoko tsa mojaro.
.Transformer ea ho itšehla thajanas
Tsepamisa maikutlo ho arohanyo ya galvanic ho ena le phetoho ya motlakase. Le hoja mehlala e meng e boloka karolelano ya ho reteleha ha 1:1, karolo ya yona ya bohlokwa ke ho roba ditsela tsa motlakase tse otlolohileng pakeng tsa mohlodi le mojaro ho netefatsa polokeho.
- Filosofi ea Moralo
Li-Transformer tse Tloaelehileng
E hahiloe ka ho kopanya ha makenete ho nolofalletsang phetoho ea motlakase. Li-Autotransformer (mofuta o monyenyane) li arolelana mapheo bakeng sa moralo o monyane empa ha li na bokhoni ba ho itšehla thajana.
Li-Transformer tsa ho Isolate
E na le karohano e habeli e nang le tšireletso ea motlakase. Mefuta e tsoetseng pele e kenyelletsa likheo tsa Faraday ho thibela lerata la mokhoa o tloaelehileng le li-transients.
- Litlhaloso tsa Polokeho
| Paramethara | Transformer e Tloaelehileng | Transformer ea ho itšehla thajana |
| Matla a Dielectric | 1,000V (e tloaelehileng) | ≥1,500V (e latela IEC 61558-1) |
| Ho dutla ha jwale | Ho fihlela ho 3.5mA |
|
| Sebopeho sa ho thella | Ho se nke lehlakore ho thehiloe fatše | Sebaka se phaphametseng kapa se khethileng ho thea mobu |
- Maemo a Kopo
Li-Transformer tse Tloaelehileng
Mekhoa ea taolo ea othomathike ea indasteri
Morero o akaretsang Kabo ea Matla (mohlala, phetoho ea 380V→220V)
Lisebelisoa tse amang litšenyehelo ka hloko ntle le litlhoko tse thata tsa polokeho
Li-Transformer tsa ho Isolate
Lisebelisoa tsa ho etsa litšoantšo tsa bongaka (li-skena tsa MRI/CT)
Lisebelisoa tsa laboratori le litsamaiso tsa molumo/video
Li-interface tsa matla a nchafatsoang (li-inverter tsa letsatsi)
- Ho kenya tshebetsong ha tekheniki
Mekhoa ea ho kenya lithapo
E tloaelehileng: Likhokahano tse tobileng tse sa nke lehlakore
Ho itšehla thajana: Mela e inehetseng ea PE/N e nang le tlhokomelo ea ho thibela ho ruruha
Tshebetso ea EMI
E tloaelehileng: E ka angoa ke lerata le tsamaisoang (li-harmoniki tsa 50/60Hz)
Ho itšehla thajana: >60dB karolelano ea ho hana mokhoa o tloaelehileng (CMRR)
- Maemo a ho Latela Melao
Tloaelehileng: IEC 60726-2 (lits'ebetso tsa indasteri)
Ho itšehla thajana: IEC 61558-1/2 (litsamaiso tsa bohlokoa-polokeho), UL 1950 (lisebelisoa tsa bongaka)
Papiso ena e hlophisitsweng e totobatsa kamoo di-transformer tse arohaneng di fanang ka melemo ya bohlokwa ya polokeho ka theknoloji e tswetseng pele ya ho kenya mocheso le ho thibela lerata, ha di-transformer tse tlwaelehileng di beha pele phetoho ya motlakase e bolokang tjhelete e ngata. Kgetho e itshetlehile hodima ditlhoko tse ikgethang tsa polokeho ya motlakase le ditikoloho tsa tshebetso.