Leave Your Message
Lihlopha tsa Litaba
Litaba tse Hlahisitsoeng

Sesebelisoa sa ho fetola

2025-08-2020

SWITCHGEAR1.jpg

Switchgear ke eng?

Dipotoloho tsa motlakase di sebetsana le bokgoni ba mojaro bo rerilweng esale pele ka moralo. Di lokela ho laolwa ho thibela motlakase o feteletseng ho feteletsa terata le ho jara tsamaiso ka boima bo feteletseng. Sistimi e imetsweng ke boima ke kotsi ya polokeho e ka senyang dikarolo tsa bohlokwa esita le ho baka mollo wa motlakase. Switchgear e teng ho laola thepa ya motlakase le ho netefatsa hore e sebetsa ka polokeho le ka katleho.

Likarolo tsa switchgear li kenyelletsa liswitch tsa ho tima motlakase, li-circuit breaker, li-fuse le li-arrestor tsa lehalima tse tsamaisang kapa tse sitisang maqhubu a motlakase a phallang. Ha ho hlaha phallo ea motlakase, switchgear e sitisa phallo ea motlakase 'me e sireletsa litsamaiso tsa motlakase tšenyong ea ho jara matla a mangata.

Ke hobane'ng ha switchgear e hlokahala?

Li-switchgear li etselitsoe ho sireletsa lisebelisoa tse hokahantsoeng le phepelo ea motlakase kotsing ea ho imeloa ke motlakase. Lisebelisoa tsa ho chencha motlakase li sireletsa mechine, lisebelisoa, lienjene le litsamaiso tse ling tse nang le potoloho ea motlakase ka ho laola le ho laola phallo ea motlakase.

Switchgear e boetse e sireletsa litsebi tsa tlhokomelo le tokiso kotsing ka ho li arola ho lipotoloho tse nang le matla. Litsebi tsa motlakase le lits'ebeletso tsa motlakase li itšetleha ka switchgear ho fokotsa matla a lisebelisoa ho leka potoloho ka mokhoa o sireletsehileng, ho etsa mesebetsi ea tlhokomelo le ho hlakola liphoso tse theohelang.

Sesepa sa switchgear se sebetsa joang?

Lisebelisoa tsa switchgear li thibela tšenyo le litšitiso tsa litšebeletso ka ho laola phallo ea motlakase ka har'a sistimi ea motlakase. E ka arola lipotoloho tse amehileng ha ka nako e ts'oanang e fana ka motlakase ho tsoa mehloling e mengata ho ea mojarong. Ha phallo ea motlakase kapa phoso e baka sehahlauli sa potoloho ka har'a kopano ea switch ea motlakase, likarolo tse tšehetsang li sitisa le ho ntša motlakase ka har'a potoloho e imetsoeng ha li ntse li boloka tšebeletso lipotolohong tse sebetsang.

Li-switchboard khahlanong le li-switchgear
Li-switchboard le li-switchgear li sebeletsa mesebetsi e fapaneng haholo. Li na le likarolo tse fapaneng tsa hardware, motlakase, ts'ebeliso le maemo a polokeho. Li-switchboard ke lisebelisoa tse nang le motlakase o tlase tse sebelisoang libakeng tsa khoebo le tsa indasteri ho fetisetsa, ho fetisetsa tsela bocha le ho aba motlakase ho li-transformer ka bomong, litsamaiso tsa taolo, liphanele tsa potoloho le meroalo. Switchgear e laola phallo ea motlakase ho thibela ho phahama ha matla a kotsi.

Mefuta ea li-switchgear
Amerika Leboea, mefuta e meraro ea lisebelisoa tsa ho fetola motlakase e arotsoe ho latela maemo a ANSI/IEEE le NEC 2014 bakeng sa litsamaiso tsa motlakase tse fanang ka maqhubu a fapanyetsanang.

1. Lisebelisoa tsa ho chencha motlakase tse nang le motlakase o tlase li sebelisoa bakeng sa litsamaiso tse sebetsang ka tlase ho kilovolt (kV) e le 'ngoe.

2. Lisebelisoa tsa ho chencha motlakase tsa motlakase o mahareng li sebetsa ka motlakase ho tloha ho 1 kV ho isa ho 75 kV

3. Lisebelisoa tsa ho chencha motlakase tse nang le motlakase o phahameng li sebetsa ka motlakase ho tloha ho 75 kV ho isa ho hoo e ka bang 230 kV.

Lisebelisoa tsa ho chencha motlakase li lokela ho bolokoa ka har'a sekwahelo se loketseng se lekantsoeng ke NEMA ha se sebelisoa kantle ho se sireletsa khahlanong le ho senyeha le maemo a leholimo.

● Sesebelisoa sa ho fetola motlakase o tlase
Switchgear e nang le motlakase o tlase e na le diswitjhi, di-circuit breaker tse nang le motlakase o tlase, di-earth leakage circuit breaker, di-miniature circuit breaker (MCBs), di-molded case circuit breaker (MCCBs), di-fuse tse nang le bokgoni bo phahameng ba ho sitisa motlakase (HRC), le di-insolator tsa motlakase tse tswang kantle.

Lisebelisoa tsena li ka hlophisoa bakeng sa tšebeliso ea ka tlung kapa kantle 'me li ka lekanngoa bakeng sa tšebeliso ea li-volts tse 208, li-volts tse 240, li-volts tse 480, le li-volts tse 600 ho fihlela ho li-volts tse 1000. Meaho ea indasteri, ea masepala le ea khoebo hangata e sebelisa switchgear ea motlakase o tlase ho laola phepelo ea motlakase ho HVAC, mabone le litsamaiso tse ling tsa meaho.

● Sesebelisoa sa ho fetola motlakase se mahareng
Sesebediswa sa ho fetola motlakase se mahareng se sebedisa di-insulator tsa oli, kgase, kapa vacuum le di-circuit breaker ho sitisa phallo ya motlakase haeba ho na le ho phahama ha motlakase kapa phoso ya sistimi. Di-insulator di sireletsa le ho phodisa dikarolo tse ka hara disebediswa tsa ho fetola motlakase, ha se-circuit breaker se hula dikgokelo tsa potoloho ho ntsha arc.

Litsamaiso tsa kahare le kantle hangata li lekantsoe ho 5 kV, 12 kV, 15 kV, le 35 kV ho fihlela ho 75 kV ho bontša motlakase o moholo ka ho fetisisa oo li ka o sebeletsang. Sesebelisoa sena sa ho fetola motlakase se sebelisoa hangata liteisheneng tse hlahisang le liteisheneng tse nyenyane tsa phetisetso. E boetse e sebelisoa ho laola lienjene, lipotoloho tsa phepelo, le lijenereithara litsing tsa indasteri le tsa khoebo.

● Sesebelisoa sa ho fetola motlakase se phahameng
Sesebelisoa sa ho fetola motlakase se nang le motlakase o phahameng se laola litsamaiso tsa motlakase tse sebetsang bonyane ka 75 kV. Sesebelisoa sena sa ho fetola motlakase se sebelisa li-disconnector, li-switch tsa ho kenya motlakase, mekhoa ea ho fetola motlakase o nang le motlakase o phahameng, li-fuse le li-circuit breaker ho laola, ho laola, ho sitisa, ho arola le ho ntša motlakase o mongata.

Hobane phoso efe kapa efe ea motlakase e ka baka arc e matla haholo, lisebelisoa tsa ho fetola motlakase tse nang le motlakase o phahameng li hloka ho sebetsa ka ho tsoelang pele le ka mokhoa o tšepahalang. Lisebelisoa tsena tsa ho fetola motlakase li bohlokoa bakeng sa ts'ebetso e nang le liketsahalo tse ngata tsa liphoso tsa motlakase 'me li hloka ho fokotsa matla a lisebelisoa khafetsa. Hangata li fumanoa lits'ebetsong tse kholo tsa phetiso ea motlakase le kabo le lits'ebetsong tsa khoebo kapa tsa indasteri.

Mefuta ea ho kenya li-switchgear
Ka di-voltage tse fapaneng, switchgear e ka boela ya sebedisa mefuta e fapaneng ya ho kenya mocheso ho sireletsa disebediswa tse nang le matla mathateng a motlakase. Di-switchgear tse kwahetsweng di sebedisa mefuta e latelang ya ho kenya mocheso.

● Lisebelisoa tsa ho chencha motlakase tse sireletsang peterole
Sesebediswa sa ho fetola mocheso se nang le khase (GIS) se sebedisa di-circuit breaker tse sebedisang kgase ya sulfur hexafluoride (SF6) e nang le kgatello ho sireletsa di-conductor le di-contact le ho tima motlakase wa arc o bakwang ke phoso ya motlakase. Carbon dioxide (CO2) ke mokhoa o mong o sa tshwarweng ke tlelaemete ho feta SF6. Ho nkela SF6 sebaka ka CO2 ho ka fokotsa ho ntshuwa ha kgase e futhumatsang lefatshe ka ditone tse 10 nakong ya bophelo ba sesebediswa.

● Lisebelisoa tsa ho chencha motlakase tse nang le moea o kenang ka har'a insulation
Sesebediswa sa ho fetola motlakase se nang le insulation ya moya (AIS) se sebedisa di-circuit breaker tse sebedisang moya o hatelletsoeng kapa matla a makenete ho atolosa arc hore e tle e ikgantshe.

● Lisebelisoa tsa ho chencha motlakase tse sireletsang oli
Sesebediswa sa ho fetola oli se kentsweng ka oli se etsa hore oli ya diminerale e be mouoane tseleng ya arc e hlahiswang ha dikgokelo tse tsamaisang motlakase di arohana mme di e potoloha ka bubble ya kgase ya haeterojene e ntshang motlakase mme e thibele arc ho kgutlela morao.

● Lisebelisoa tsa ho chencha motlakase tse kentsweng ka vacuum
Sesebediswa sa ho fetola motlakase se kentsweng ka vacuum se fedisa dimolekhule tse ka fetolwang ka motlakase. Arc efe kapa efe e tla otlollwa le ho fediswa leha motlakase o ntse o phahama.

Ho kenya li-switchgear
Basebetsi ba nang le laesense e nepahetseng ba tlameha ho kenya lisebelisoa tsohle tsa ho chencha motlakase ho latela melao ea polokeho e sebetsang, litataiso tsa kaho le litaelo tsa moetsi. Ho kenya hantle ho netefatsa ts'epahalo e ntle ea ts'ebetso.