Ha ho tluoa tabeng ea li-transformer,PT(Transformer e ka bang tengleCT(Transformer ea hajoale) li tšoana le duo e matla ea lefats'e la motlakase—Batman le Robin. Ba kanna ba se ke ba sebelisa leseli joalo ka transformer ka boeona, empa bana ba babeli ba sebetsa ka morao ho liketsahalo ho netefatsa hore ntho e 'ngoe le e 'ngoe e sebetsa ka mokhoa o sireletsehileng le o sebetsang hantle. A re hlahlobeng hore na ba sebetsa joang ka boloi ba bona mefuteng e fapaneng ea li-transformer.

PT: Moqoqo oa Voltage

TheTransformer e ka bang teng (PT)ke motho eo u mo ratang haholo bakeng sa ho theola motlakase o phahameng ho ea boemong bo laolehang. Ak'u nahane u sebetsana le motlakase o moholo oa 33 kV (kapa o phahameng le ho feta) tsamaisong ea hau ea motlakase—o kotsi 'me ka sebele ha se ntho eo u ka ratang ho e lekanya ka ho toba. Ke hona moo PT e kenang teng. E fetola motlakase oo o phahamisang moriri hore e be ntho eo li-meter le li-relay tsa hau li ka e sebetsanang ntle le ho fufuleloa, hangata e o theola ho ntho e kang 110 V kapa 120 V.

Joale, u fumana li-PT li sebetsa hokae?

  • Li-transformer tsa phetiso ea motlakase o phahameng: Tsena ke lithunya tse kholo tsa gridi ea motlakase, tse sebetsanang le li-voltage kae kapa kae ho tloha ho 110 kV ho isa ho 765 kV. Li-PT mona li etsa bonnete ba hore u ka beha leihlo le ho lekanya motlakase ka mokhoa o sireletsehileng u le hole.
  • Li-transformer tsa seteishene se senyenyane: Li-PT li sebetsa liteisheneng tse nyenyane ho lekola le ho laola maemo a motlakase pele a ajoa ho bareki ba indasteri kapa ba bolulo.
  • Li-transformer tsa tšireletso le metering: Litsamaisong tseo ho tsona ho lekola motlakase ho leng bohlokoa bakeng sa polokeho le ho lefisa, li-PT lia kenella ho fana ka lipalo tse nepahetseng tsa motlakase bakeng sa likamore tsa taolo, li-relay le lisebelisoa tsa tšireletso.

PT e tšoana le mofetoleli ea khutsitseng, ea bokelletsoeng konsareteng e lerata ea motlakase, ea nkang lintlha tseo tse tabolang litsebe tsa 110 kV 'me a li fetola molumo o bonolo oo lisebelisoa tsa hau li ka o tšoarang.

CT: Tamer ea Hona Joale

Jwale, ha re bueng kaTransformer ea Hona Joale (CT), mokoetlisi oa sistimi ea motlakase. Ha motlakase o qala ho kobeha mesifa ea oona ka li-amps tse likete tse phallang ka har'a transformer ea hau, CT ea kenella ho e theola ho ea boemong bo sireletsehileng—hangata bo pakeng tsa 5 A kapa 1 A.

U tla fumana li-CT li ntse li le teng:

  • Transformer ea Kabos: Banna bana ba sebeletsa libaka tsa bolulo kapa tsa khoebo, hangata ba sebetsa ka motlakase o kang 11 kV ho isa ho 33 kV. CT mona e netefatsa tlhokomelo le tšireletso ea hajoale, e ntse e lekola hore na lero le phalla hakae ka har'a mela.
  • Li-Transformer tsa Matla liteishene tse nyenyane: Li-CT li beha leihlo motlakase litsing tse nang le motlakase o phahameng moo li-transformer li theolang motlakase ho tloha maemong a phetisetso (mohlala, 132 kV kapa ho feta) ho ea maemong a kabo. Li bohlokoa bakeng sa ho lemoha liphoso le ho qala lisebelisoa tsa tšireletso pele ho hong ho tsamaea hampe.
  • Li-transformer tsa indasteri: Lifekthering kapa libakeng tse boima tsa indasteri, hangata li-transformer li sebetsana le meroalo e boima, 'me li-CT li teng ho lekola maqhubu a maholo. Haeba ho na le ho hong ho sa tsamaeeng hantle, CT e fetisetsa tlhahisoleseling lits'ebetsong tsa tšireletso tse koalang lintho pele lisebelisoa li halikoa.

Nahana ka CT e le sesebelisoa sa ho thiba mosi oa koloi sehlopheng—e boloka phallo ea metsi e le taolong e le hore e se ke ea sitisa litsamaiso tsa hau tsa tšireletso, 'me haeba lintho li e-ba le moferefere haholo, CT e etsa bonnete ba hore motho e mong o fihla sebakeng sa tšohanyetso.

Hobaneng PT le CT li le Bohlokoa

Hammoho, PT le CT li etsa sehlopha sa mapolesa a ho qetela lefatšeng la transformer. Ke bona ba etsang hore basebetsi ba khone ho beha leihlo le ho laola ts'ebetso ea transformer ka mokhoa o sireletsehileng ntle le ho atamela sebata ka 'mele (ntšepe, ha u batle ho atamela mofuta oo oa motlakase le motlakase ntle le tšireletso e tebileng). Hore na ketransformer ea kabosebakeng sa heno kapatransformer ea matla a phahamengMatla a fepelang ho pholletsa le metse yohle, di-PT le di-CT di dula di le teng, di boloka motlakase le motlakase di le moleng.

Ntlha e Monate: Ho Hlokomela Mahlakore ka Bobeli

Na o kile wa ipotsa hore na ke hobaneng ha bili ya hao ya motlakase e nepahetse hakaale? O ka leboha dingaka tsa motlakase le tsa motlakase kali-transformer tsa ho lekanyaBa etsa bonnete ba hore khamphani ea litšebeletso le moreki ba tseba hantle hore na motlakase o sebelisoa hakae ka ho theola motlakase ka nepo le ho lekanya motlakase le motlakase. Kahoo, e, PT le CT li boloka lintho li lekana ebile li lekana lipheletsong ka bobeli tsa gridi ea motlakase.

Qetello

Kahoo, ebang ke transformer e telele ea phetiso kapa transformer e sebetsang ka thata ea kabo,PT le CTke bahale ba sa binoang ba bolokang ntho e 'ngoe le e 'ngoe e sebetsa hantle. Ba laola motlakase o phahameng le maqhubu a maholo e le hore basebetsi, li-relay le limithara ba ka li sebetsana ntle le sutu ea superhero. Nakong e tlang ha u bula switch ea lebone, hopola—ho na le sehlopha sohle sa bahlokomeli ba motlakase ba etsang bonnete ba hore motlakase le motlakase lia itshwara.