Leave Your Message
Lihlopha tsa Litaba
Litaba tse Hlahisitsoeng

Lihlahisoa–Linyeoe tsa ho Qetella

2025-07-19

Ka 2024, re ile ra isa transformer ea 12 MVA Philippines. Transformer ena e na le matla a lekantsoeng a 12,000 KVA 'me e sebetsa e le transformer e theohelang ka tlase, e fetolang motlakase oa mantlha oa 66 KV ho motlakase oa bobeli oa 33 KV. Re sebelisa koporo bakeng sa thepa e kobehang ka lebaka la ho tsamaisa motlakase hantle, ho sebetsa hantle ha mocheso le ho hanyetsa mafome.
E entsoe ka theknoloji ea morao-rao le thepa ea maemo a holimo, transformer ea rona ea matla ea 12 MVA e fana ka ts'epo le ho tšoarella ka mokhoa o ikhethang.
Ho JZP, re netefatsa hore transformer e 'ngoe le e 'ngoe eo re e fanang e feta tekong e felletseng ea kamohelo. Re motlotlo ho boloka rekoto e se nang sekoli ea lefela ka lilemo tse fetang leshome. Li-Transformer tsa Matla li entsoe ho fihlela maemo a thata a IEC, ANSI, le litlhaloso tse ling tse etellang pele tsa machaba.
 
Sekhahla sa Phepelo
Sehlahisoa: Transformer ea Matla e qoelitsoeng ka Oli
Matla a Lekantsoeng: Ho fihlela ho 500 MVA
Motlakase oa Motheo: Ho fihlela ho 345 KV
 
Tlhaloso ea Tekheniki
Tlhaloso ea transfoma ea matla ea MVA ea 12 le leqephe la data

Mohlala SFZ11-12 MVA-66/33KV
Mofuta Transformer ea motlakase e qoelitsoeng ea 0il
E tloaelehileng IEC60076
Matla a Lekantsoeng 12000 KVA
Maqhubu 60HZ
Mokhahlelo 3
Mofuta oa ho Pholisa HA SE EMELETSENG
Motlakase oa Pele 66 KV
Motlakase oa Bobeli 33 KV
Lisebelisoa tsa ho Tsoa Koporo
Sehlopha sa Vector Selemo sa 1
Ho se sireletsehe 10%
Tlanya Sefetola-phetoho OLTC
Sebaka sa ho Tlanya ± 8*1.25%
Lisebelisoa E tloaelehileng
Litlhaloso Ha e eo

Mokhoa oa ho pholisa oa Transformer e qoelitsoeng ka oli hangata e kenyelletsa ho sebelisa oli ea transformer e le sesebelisoa sa mantlha sa ho pholisa. Oli ena e sebeletsa merero e 'meli e meholo: e sebetsa e le sesebelisoa sa motlakase 'me e thusa ho qhala mocheso o hlahisoang ka har'a transformer. Mona ke mekhoa e meng e tloaelehileng ea ho pholisa e sebelisoang ho li-transformer tse qoelitsoeng ka oli:
1. Oli ea Moea oa Tlhaho oa Tlhaho (ONAN)
● Tlhaloso:
Mokhoeng ona, convection ea tlhaho e sebelisoa ho potoloha oli ka har'a tanka ea transformer.
o Mocheso o hlahisoang ke li-winding tsa transformer o monngoa ke oli, ebe e nyoloha ebe e fetisetsa mocheso maboteng a tanka.
Mocheso o ntano qhalanyetsoa moeeng o potolohileng ka ho fetisoa ha moea ka tlhaho.

● Lisebelisoa:
o E loketse di-transformer tse nyane moo mocheso o hlahisoang o seng o feteletseng.

● Tlhaloso:
Mokhoa ona o ts'oana le oa ONAN, empa o kenyelletsa ho potoloha ha moea ka matla.
o Lifene li sebelisoa ho foka moea holim'a libaka tsa radiator tsa transformer, ho ntlafatsa ts'ebetso ea ho pholisa.

● Lisebelisoa:
o E sebediswa ditransfoma tsa boholo bo mahareng moo ho hlokahalang phodiso e eketsehileng ka nqane ho phallo ya moya wa tlhaho.

● Tlhaloso:
Ho OFAF, oli le moea li tsamaisoa ka bobeli ho sebelisoa lipompo le lifene, ka ho latellana.
o Lipompo tsa oli li potoloha oli ka har'a transformer le li-radiator, ha lifene li qobella moea ho pholletsa le li-radiator.

● Lisebelisoa:
o E loketse di-transformer tse kgolo moo convection ya tlhaho e sa lekaneng bakeng sa ho phodisa.

● Tlhaloso:
Mokhoa ona o sebedisa metsi e le mokero o mong wa ho phodisa.
o Oli e potoloha ka di-heat exchanger moo metsi a phodisang oli.
Metsi a ntoo phodiswa ka sistimi e arohaneng.

● Lisebelisoa:
E sebelisoa li-transformer tse kholo haholo kapa lits'ebetsong moo sebaka sa ho pholisa moea se fokolang 'me ho hlokahala bokhoni bo phahameng.

● Tlhaloso:
o Ho tšoana le OFAF, empa ka phallo ea oli e lebisitsoeng haholoanyane.
o Oli e tsamaisoa ka likanale kapa liphaephe tse itseng ho ntlafatsa katleho ea ho pholisa libakeng tse itseng tse chesang ka har'a transformer.

● Lisebelisoa:
o E sebediswa ditransfoma moo ho hlokahalang phodiso e reretsweng ho laola kabo e sa lekanang ya mocheso.

● Tlhaloso:
o Ena ke mokhoa o tsoetseng pele oa ho pholisa moo oli e lebisitsoeng ho phalla litseleng tse itseng ka har'a transformer, ho netefatsa hore e pholisa ka sepheo se itseng.
o Mocheso o fetisetsoa metsing ka li-heat exchanger, ka ho qobelloa ho potoloha ho qhala mocheso ka katleho.

● Lisebelisoa:
o E loketse di-transformer tse kgolo haholo kapa tse nang le matla a mangata ditirisong tsa indasteri kapa tsa thuso moo taolo e nepahetseng ya mocheso e leng bohlokwa.

2. Oli ea Tlhaho e Lefelloang ke Moea (ONAF)
3. Sefofane se qobelloang ka oli (OFAF)
4. Oli e qobelloang ka metsi (OFWF)
5. Sefofane se Tsamaiswang ke Oli (ODAF)
6. Metsi a qobelloang ke oli (ODWF)