.1. Mesebetsi ea Bohlokoa le Karolo ea Indasteri.

Switchgear e sebetsa e le mokokotlo oa litsamaiso tsa motlakase tse mahareng le tse phahameng (MV/HV), e phetha mesebetsi e meraro ea bohlokoa bakeng sa li-transformer:

  • .Kabo ea Matla: E tsamaisa motlakase ho tloha ho di-transformer ho ya meroalong ka di-feeder, di-busbars le disebediswa tsa tshireletso.
  • .Tšireletso ea Liphoso: E sitisa maqhubu a motlakase ka har'a li-millisecond (mohlala, bokhoni ba ho robeha ha potoloho e khuts'oane ea 31.5kA–40kA) ho thibela tšenyo ea lisebelisoa.
  • .Ho itšehla thajana ka polokeho: E netefatsa tlhokomelo e sireletsehileng ka ho kopanya li-interlock tsa mechini le mekhoa ea ho thella fatše.

Mohlala, sistimi ea 12kV e hloka sebaka se fokolang sa ho tloha mohatong ho ea fatše sa 125mm (se sireletsang moea) kapa 40mm (se sireletsang khase) ho thibela ho kobeha ha mokoloko.

.

.2. Mefuta le Moralo oa Meaho.

Lihlopha tsa li-switchgear le litlhaloso tsa bohlokoa:

Sehlopha.

.Mofuta​

.Mohlala​

.Li-parameter tsa bohlokoa

.Kopo​

.Ho kenya mocheso

Ho kenya mocheso o kenang ka moea (AIS)

KYN28A-12

Motlakase o lekantsoeng: 12kV, Phoso ea hona joale: 40kA

Liteishene tse nyenyane tsa indasteri

 

Ho thibela khase (GIS)

Siemens 36kV GIS

Moralo o monyane (o boloka sebaka ka 50%), khase ea SF6

Liteishene tse nyenyane tsa litoropo

.Mosebetsi​

Sesebelisoa sa ho thiba mojaro

ABB ZS1

E lekantsoe hona joale: 630A, Nako ea ho robeha:

Marangrang a kabo

 

Yuniti e ka sehloohong ea lesale (RMU)

Eaton HICOS

Sehatsetsi sa potoloho ea vacuum, se sireletsang mocheso ntle le SF6

Kopanyo ea matla a nchafatsoang

 

.Likarolo tsa Bohlokoa:

 

  • .Sehatsetsi sa Potoloho sa Vacuum (VCB)​: E fana ka mesebetsi ea mechini e fetang 10,000 e nang le khanyetso ea ho kopana le
  • .Libaesekele tsa libese: Di-conductor tsa koporo kapa tsa aluminium (tse nang le karolo e tshekaletseng ≥100×10mm²) tse nang le botsitso ba mocheso ho fihlela ho 40kA/4s.
  • .Litšireletso tsa Tšireletso: Disebediswa tse latelang IEC 61850 bakeng sa ho lemoha motlakase o feteletseng, phapang, le arc-flash.

.3. Litlhaloso tsa Tekheniki le Maemo.

  • .Litekanyetso tsa Voltage:
  • MV: 3.3kV–36kV (e tloaelehileng li-grid tsa indasteri).
  • HV: 66kV–800kV (marangrang a phetiso).
    • .Maemo a ho kenya mocheso:

Motlakase oa Sisteme

Matla a ho mamella maqhubu (1min)

Ho mamella Tšusumetso ea Lehalima

12kV

42kV

75kV

40.5kV

95kV

185kV

  • .Litšobotsi tsa Polokeho:
  • .Li-Interlock tse hlano tse thibelang: E thibela ho kenngwa ha matla ka phoso (mohlala, di-switch tsa ho kgaola mojaro di ke ke tsa kwala ntle le haeba di-circuit breaker di butswe).
  • .Phomolo ea Khatello: Diphanele tse sa phatloheng (mohlala, aluminium ya 0.8mm) dikhase tsa arc tsa moya tse ka bang ≤50kPa ho sireletsa basebetsi.

.4. Tataiso ea Khetho le Tlhokomelo.

  • .Khetho e Tsamaiswang ke Kopo:
  • .Libaka tsa Hona Joale tse nang le Phoso e Phahameng: Sebelisa SF6-insulated GIS bakeng sa matla a dielectric a ntlafetseng.
  • .Tikoloho e Bohloko: Khetha li-enclosure tse nang le tekanyo ea IP54 tse nang le masela a sa senyeheng.
    • .Teko ea Kamehla:
  • .Khanyetso ea ho ikopanya: ≤100μΩ (e lekantsoe ka micro-ohmmeter).
  • .Teko ea Dielectric: 1.2/50μs phallo ea lehalima (± 10% mamello).
  • .Ho Tšoarella ha Mekaniki: Mesebetsi e fetang 5,000 bakeng sa li-circuit breaker.

.5. Mekhoa e Hlahang.

  1. .Ho fetola dijithale:
  • Smart switchgear e kopanya di-sensor tsa IoT bakeng sa ho beha leihlo mocheso wa nako ya sebele, ho thothomela le ho ntsha mosi ka karolo.
  • Mohlala: Sethala sa Schneider Electric sa EcoStruxure se nolofalletsa tlhokomelo e bolelang esale pele ka tlhahlobo ea leru.
    1. .Botsitso:
  • Mekhoa e meng e se nang SF6 (mohlala, vacuum kapa solid-insulation) e fokotsa ho ntšoa ha likhase tse futhumatsang lefatše ka 95%.
    1. .Moralo oa Modular:
  • Likhabote tsa ho kenya le ho bapala (mohlala, UniGear ZS1 ea ABB) li khutsufatsa nako ea ho kenya ka 40%.

.Litšupiso.

  • IEC 62271-200:Sesebelisoa sa ho switjha se kentsweng ka tshepe se kentsweng ka kgase
  • IEEE C37.2:Tekanyetso bakeng sa linomoro tsa ts'ebetso ea sesebelisoa sa sistimi ea motlakase
  • Gridi ea Naha UK:Mekhoa e metle ea tlhokomelo ea li-switchgear