+86 18068001229 Li-Transformer tse kentsoeng ka Pad tsa JZP tsa Mokhahlelo o le Mong: Boenjiniere bo Nepahetseng bakeng sa Kabo e Tšepahalang ea Matla
Li-transformer tsa JZP tse kentsoeng ka phaposi e le 'ngoe li entsoe hore li fete maemo a lefats'e ha li ntse li fana ka ho tenyetseha le ho tšoarella ho sa bapisoeng bakeng sa mefuta e fapaneng. Kabo ea Matla E etselitsoe ho latela le ho feta litlhokoLitekanyetso tsa ANSI, IEEE, DOE, CSA, le NEMA, di-transformer tsena di kenyeletsa dikarolo tse tswetseng pele tsa polokeho le kaho e matla, di netefatsa tshebetso e ntle ka ho fetisisa dikopong tsa indasteri, tsa kgwebo le tsa bodulo.
.Likarolo tsa Bohlokoa le Litlhaloso.
.Ho Latela Melao le Polokeho.
- E netefalitsoe ka botlalo kaLenane la UL/cUL, CSA, 'me ea lekoa hoANSI IEEE C57.12.00,CSA C22.2 Nomoro ea 66leLitekanyetso tsa katleho ea DOE 2016.
- E hlomelitsoe kaMokelikeli oa Envirotemp FR3™bakeng sa khanyetso e matla ea mollo le polokeho ea tikoloho, hammoho le likhetho tsa oli tsa setso tse sireletsang liminerale.
.Litlhophiso tse ka fetoloang.
- .Sebaka sa Bokgoni: 15–250 kVA, e ka feto-fetohang le lits'ebetso ho tloha lits'ebetsong tse nyane tsa bolulo ho isa meroalong e boima ea indasteri.
- .Ho tenyetseha ha Voltage:
- Metlakase ea mantlha: 34.5 kV–7.2 kV (mefuta e ka fetoloang e fumaneha).
- Metlakase ea bobeli: 120–600 V (120-240 V, 240-480 V, 347/600 V, kapa litharollo tse etselitsoeng uena).
- .Dikgetho tsa Phepelo: Litlhophiso tsa sekgoqetsane kapa radial ho latela ditlhoko tsa gridi.
.Kaho e Matla.
- .Thepa ea Bolulo: Tšepe e bobebe kapa boikhetheloLitanka tse 304 tsa tšepe e sa rusengbakeng sa ho hanyetsa mafome libakeng tse thata.
- .Ho kenya le ho pholisa: Mekhoa e tsoetseng pele ea ho thibela mocheso le ho pholisa ha convection ea tlhaho bakeng sa taolo e tšepahalang ea mocheso.
- .Litekanyetso tsa BIL: 30–150 kV, ho netefatsa ho mamella ho phahama ha motlakase.
.Bokgoni le Tshebetso.
- Meralo e sebetsang hantle haholo e lumellanang leMaemo a eneji a DOE 2016, ho fokotsa litšenyehelo tsa ts'ebetso.
- Mabili a tahlehelo e tlase le li-core tsa makenete tse ntlafalitsoeng li ntlafatsa paballo ea matla.
.Lisebelisoa le Kopanyo.
- E tsamaisana le lihlahisoa tsa boleng bo holimo joalo kaABB, Eaton, le Qualitrolbakeng sa ts'ebetso e ntlafalitsoeng (mohlala, litsamaiso tsa ho beha leihlo, ts'ireletso ea ho phahama ha maqhubu).
- Li-converter tsa pompo tse ka fetoloang (liphetoho tsa 2×2.5%) bakeng sa taolo e nepahetseng ea motlakase.
.Tlhahiso le Phano.
- .Bokgoni: HolimoLiyuniti tse 600 ka khoeli, ho netefatsa phetoho e potlakileng ntle le ho beha boleng kotsing.
- .Lead time: Thomello e potlakileng ho Libeke tse 4-8, e tshehetswang ke tshebetso e nolofaditsweng ya tlhahiso.
.Ke Hobane'ng ha U Khetha JZP?.
Li-transformer tsa JZP li entsoe bakeng sa nako e telele, botsitso le ho ikamahanya le maemo. Ebang ke ho ntlafatsa litsamaiso tsa khale kapa ho kenya meralo ea motheo e mecha, litharollo tsa rona li etelletsa pele polokeho, bokgoni, le ho latela melaoDikgetho tse ka fetolwang—ho tloha ho ditekanyetso tsa motlakase ho ya ho thepa—di netefatsa kopanyo e se nang sekoli ho gridi efe kapa efe ya motlakase.
Bakeng sa litokomane tse qaqileng tsa tekheniki kapa ho buisana ka litlhoko tse ikhethileng tsa projeke, ikopanye le sehlopha sa boenjiniere sa JZP kajeno.