Leave Your Message
Lihlopha tsa Litaba
Litaba tse Hlahisitsoeng

Lintho tsa Bohlokoa tsa Ntlafatso ea Matla a Indasteri: Litharollo tse 6 tse Ikhethang tsa Li-transformer tsa JZP Medium/High Voltage

2026-01-28

Mehleng ea phetoho e potlakileng ea motlakase oa indasteri le matla, li-transformer tsa motlakase o mahareng/o phahameng (MV/HV) li fetohile mokokotlo oa litsamaiso tsa matla a indasteri. Jha ka moetapele oa lefats'e ka bophara litharollong tsa motlakase, JZP​ e qapile sehlopha sa li-transformer tsa MV/HV tse etselitsoeng ho sebetsana le litlhoko tse ikhethang tsa makala a fapaneng a indasteri. Sengoloa sena se hlahloba lits'ebetso tse tšeletseng tsa bohlokoa tsa indasteri moo li-transformer tsa JZP li fanang ka ts'ebetso ea phetoho, e tšehetsoang ke temohisiso ea tekheniki le lithuto tsa linyeoe tsa lefats'e la nnete.

 

  1. Tlhahiso e Bohlale le Boiketsetso​

 

Phephetso: Lifeme tsa sejoale-joale li itšetlehile ka mechini e laoloang ka nepo le litsamaiso tse sebelisoang ke IoT, tse hlokang motlakase o tsitsitseng le tahlehelo e fokolang ea matla.

 

Tharollo ea JZP:

 

Li-transformer tsa MV tse etselitsoeng motho ka mong (mohlala, 110kV/6.3kV) tse nang le tahlehelo ea moroalo e ka tlase ho 0.5% li netefatsa ts'ebetso e ntle ea matla, e leng ea bohlokoa bakeng sa mela ea kopano ea liroboto le mechini ea CNC.

 

Transformer ea Mofuta o OmilengKa ho kenya mocheso oa resin ea epoxy ho felisa likotsi tsa mollo libakeng tse amehang lerōleng joalo ka tlhahiso ea semiconductor.

 

Mekhoa e tsoetseng pele ea taolo ea mocheso e boloka ts'ebetso maemong a mocheso o phahameng (ho fihlela ho +40°C).

 

Thuto ea Nyeoe: Setsi sa likoloi sa Jeremane se fokolitse litšenyehelo tsa matla ka 18% kamora ho kenya li-transformer tsa mofuta o omileng tsa JZP tsa 10MVA, tse ntlafalitsoeng bakeng sa taolo ea ho sotha ha harmonic.

 

  1. Kopanyo ea Matla a Nchafatsang​

 

Bothata: Mapolasi a letsatsi le diturbine tsa moya di hloka di-transformer tse matla ho eketsa DC/AC ya motlakase o tlase ho ya maemong a tsamaellanang le gridi.

 

Tharollo ea JZP:

 

Li-transformer tsa gridi ea 110kV/31.5MVA tse nang le sehatsetsi sa khase sa SF6 li mamella maemo a thata a kantle 'me li netefatsa ts'epo lits'ebetsong tsa lehoatata kapa tsa lebopong.

 

Meralo e thibelang ho bola (matlo a tšepe e sa ruseng a 316L) e eketsa bophelo ba 'mele libakeng tse mongobo kapa tse letsoai.

 

Kopanyo e se nang sekoli le li-inverter tse bohlale bakeng sa taolo ea motlakase o matla.

 

Thuto ea Nyeoe: Polasi ea matla a letsatsi ea 500MW Texas e sebelisitse li-transformer tsa JZP tsa 33kV/11kV, e fihletseng tekanyo ea katleho ea 99.2% le MTBF ea lilemo tse 25.

 

  1. Phuputso ea Oli le Khase

 

Bothata: Li-platform tsa leoatleng le libaka tsa ho cheka tse hole li hloka litsamaiso tsa motlakase tse sa phatloheng, tse sa hlokeng tlhokomelo e ngata.

 

Tharollo ea JZP:

 

Ha e phatlohe Transformer e omileng(Sehlopha sa I, Karolo ea 1) li latela maemo a ATEX/IECEx bakeng sa libaka tse kotsi.

 

Ho mamella potoloho e kgutshwane e phahameng (40kA/1s) le ho kenngwa ho sa thothomeleng ho netefatsa ho tshwarella dibakeng tse sebetsang ka tshisinyeho ya lefatshe.

 

Ho beha leihlo hole ka di-sensor tsa IoT ho nolofalletsa tlhokomelo e bolelang esale pele, ho fokotsa nako ya ho se sebetse ka 30%.

 

Thuto ea Nyeoe: Leoatleng le ka Leboea, 31.5MVA ea JZP Transformer e qoelitsoeng ka oliLi-compressor tsa metsing a ka tlas'a leoatle tse tsamaisoang ka matla ka lilemo tse 5 ntle le ho hloleha.

 

  1. Litsi tsa Lintlha le Mehala ea Thelefono

 

Bothata: Mesebetsi ea 24/7 e hloka nako ea ho se sebetse hantle le ho sotha ha harmonic ho sa feleng.

 

Tharollo ea JZP:

 

Li-transformer tsa lerata le tlase haholo​ (

 

Meralo ea modular e lumella likarolo tse ka fetoloang bakeng sa nako ea ho sebetsa ea lihora tse 24.

 

Oli ea ester ea tlhaho​ e fihlela maemo a polokeho ea mollo a UL 1411 bakeng sa meralo ea motheo ea bohlokoa.

 

Thuto ea Nyeoe: Setsi sa data sa hyperscale Virginia se sebelisitse li-transformer tsa modular tsa JZP tsa 10kV/400V, tse fihletseng ts'epo ea 99.999%.

 

  1. Merafo le Indasteri e Boima​

 

Bothata: Lerōle, likhase tse phatlohang, le meroalo e feto-fetohang merafong li hloka li-transformer tse thata, tse feto-fetohang.

 

Tharollo ea JZP:

 

Li-transformer tse sa keneleng lerole tse nang le tekanyo ea IP55​ tse nang le mapheo a koetsoeng​ li hanela litšila tse tsamaeang moeeng.

 

Taolo e pharaletseng ea motlakase​ (±10%) e amohela maemo a sa tsitsang a gridi libakeng tsa merafo tse hole.

 

Bokgoni ba ho jara boima bo feteletseng​ (150% bakeng sa dihora tse 2) bo tshehetsa disebediswa tse nang le matla a mangata tse sa kgaotseng jwalo ka di-crusher.

 

Thuto ea Nyeoe: Morafo oa koporo Chile o fokolitse nako ea ho sebetsa ka 40% ho sebelisoa li-transformer tse sa phatloheng tsa JZP tsa 2500kVA.

 

  1. Meralo ea Motheo ea Litoropo le Metse e Bohlale​

 

Bothata: Libaka tsa litoropo tse nang le baahi ba bangata li hloka li-transformer tse nyane, tse bolokang matla bakeng sa mabone a literateng le ho tjhaja motlakase oa motlakase.

 

Tharollo ea JZP:

 

Li-transformer tse nyane tse kentsoeng ka pad (mohlala, 100kVA) li boloka sebaka sa 40% ha li bapisoa le li-unit tsa setso.

 

Taolo ea motlakase o matla​ e tšehetsa liteishene tsa ho tjhaja ka potlako tsa EV (ho fihlela ho 150kW).

 

Tlhahlobo e bohlale ka li-platform tsa leru e nolofalletsa ho leka-lekanya mojaro ka nako ea sebele.

 

Thuto ea Nyeoe: Projekeng ea Smart City ea Dubai, li-transformer tsa JZP tsa 11kV/400V li ne li sebelisa libaka tsa ho tjhaja tsa 500+ EV ka katleho ea 98%.

 

Hobaneng JZP e Ikhetha

 

Ho Latela Melao ea Lefatše: Litifikeiti li kenyelletsa IEC 60076, IEEE C57.12.00, le UL 1561.

 

Tšoarello: Bokgoni ba ho fihlela ho 98.5% le thepa e ka sebediswang hape di fokotsa kgatello ya khabone.

 

Ho iketsetsa: Litharollo tse etselitsoeng motlakase (6.3kV–110kV), ho pholisa (ONAN/OFWF), le impedance (4%–10%).

 

Qetello​

 

Li-transformer tsa MV/HV tsa JZP li entsoe ho tsamaisa ntlafatso ea indasteri, li kopanya boenjiniere ba sejoale-joale le ho ikamahanya le maemo ho ipapisitseng le indasteri. Ho tloha lifekthering tse bohlale ho ea libakeng tsa matla a leoatleng, litharollo tsena li hlalosa bocha bokhoni ba ts'ebetso le ts'epo. Bakeng sa likhoebo tse ikemiselitseng ho sireletsa meralo ea tsona ea motlakase nakong e tlang, ho sebelisana le JZP ha se khetho feela—ke ntho ea bohlokoa ea leano.