+86 18068001229 Transformer ea High-Voltage: Tlhaloso, Melao-motheo ea Mosebetsi, le Litšebeliso
.Transformer e nang le Voltage e Phahameng ke eng?.
Transformer ea motlakase o phahameng ke sesebelisoa sa motlakase se entsoeng ka mokhoa oa ho fetola matla a motlakase lipakeng tsa maemo a motlakase, hangata se sebetsang ka har'a mefuta ea110 kV ho isa ho 500 kVLi-transformer tsena li bohlokoa haholo litsamaisong tsa phetisetso ea motlakase, li fokotsa tahlehelo ea matla nakong ea phetisetso ea motlakase e hole ha ka nako e ts'oanang li netefatsa hore motlakase o tlisoa malapeng, likhoebong le liindastering ka mokhoa o sireletsehileng. Mohlala, lifeme tsa motlakase li hlahisa motlakase ka li-voltage tse phahameng, 'me li-transformer li fetola motlakase ona—ebang li o eketsa bakeng sa phetisetso kapa li o theola bakeng sa tšebeliso ea basebelisi ba ho qetela—ho ntlafatsa bokhoni le polokeho.
.
.Transformer e Phahameng ea Motlakase e Sebetsa Joang?.
Holimo-Li-Transformer tsa Voltage sebetsa ho latela molao-motheo oatlhahiso ea motlakaseLi na le:
- .Mabili a Pele le a Bobeli: Leqeba le potileng khubu ea ferromagnetic.
- .Core: E entsoe ka tšepe ea silicon e laminated ho fokotsa tahlehelo ea motlakase oa eddy.
- .Phetoho ea Voltage: Ha motlakase o fapanyetsanang (AC) o sebediswa ho kobeha ha motlakase o ka sehloohong, o hlahisa phallo ya makenete e feto-fetohang ka hare ho motlakase. Kobeho ena e baka motlakase ho kobeha ha motlakase o ka sehloohong, mme karolelano ya diphetoho e etsa qeto ya motlakase o tswang. Diphetoho tse phahameng ho kobeha ha motlakase o ka sehloohong di hlahisa di-voltage tse phahameng, tsa bohlokwa bakeng sa phetiso ya sebaka se selelele.
.Ts'ebetso ea Tlhahiso ea Li-Transformer tse nang le Voltage e Phahameng.
Tlhahiso e kenyelletsa mehato e nepahetseng ea boenjiniere:
- .Ho phunya Likhoele: Li-conductor tsa koporo kapa tsa aluminium li kenngoa likhoeleng tsa mantlha le tsa bobeli.
- .Kopano ea mantlha: Maqephe a tšepe a laminated a bopa karolo ea mantlha ea makenete ho ntlafatsa katleho.
- .Kopanyo ea Likarolo: Likhoele le karolo e ka hare ea lepolanka lia kopanngoa, lia omisoa ho tlosa mongobo, 'me li bolokoa ka tankeng.
- .Ho kenya le ho pholisa: Oli ea diminerale kapa maro a dielectric a maiketsetso a kenngoa bakeng sa ho thibela mocheso le taolo ea mocheso.
- .Kalafo ea Vacuum: Ho kenngoa ha vacuum ho netefatsa ho thibela ho se be le letho.
- .Teko: Liteko tse matla tsa motlakase le tsa mechini li netefatsa ts'ebetso, ho kenyeletsoa ho hanyetsa ho futhumatsa, bokhoni ba mojaro, le botsitso ba mocheso.
- .Ho paka le ho tlisa thepa: Lihlahisoa tsa ho qetela li hlahlojoa boleng pele li romelloa.
.Mefuta ea Li-Transformer tse Phahameng.
- E kentswe ditsing tsa motlakase le diteisheneng tse ding bakeng sa phetiso ya motlakase o phahameng (mohlala, ditsamaiso tsa 500 kV).
- E etselitsoe bokhoni bo fihlang ho500 MVA, e nolofalletsang phetiso e sebetsang hantle ya eneji ho feta dikhilomithara tse makgolo.
- Metlakase ea ho theola motlakase (11 kV ho isa ho 33 kV) bakeng sa ts'ebeliso ea matlo, khoebo le indasteri.
- E ikarabella bakeng sa ~50% ea tahlehelo ea matla marangrang a kabo, e leng se totobatsang karolo ea bona ntlafatsong ea bokhoni.
.Transformer ea Mofuta o Omilengs.
- E pholisitsoe ke moea ebile ha e che, e loketse libaka tsa ka tlung tse kang lifektheri kapa liofisi.
- Kholo ea 'maraka e lebelletsoe ho6% CAGRho fihlela ka 2026, e susumetsoang ke litlhoko tsa polokeho.
.Li-Transformer tsa ho Tsamaea/Ho Fokotsa Mehato.
- .Mohato o Phahameng: Phahamisa di-voltage (mohlala, 13.8 kV ho isa ho 220 kV) dipolanteng tsa motlakase bakeng sa phetiso.
- .Ho theohela tlaseFokotsa motlakase (mohlala, 33 kV ho isa ho 440 V) bakeng sa polokeho ea mosebelisi oa ho qetela.
.Likarolo tsa Bohlokoa.
- .Moralo oa ho Fetoha: Mabili a koporo/aluminiamo a leka-lekanya ho tsamaisa le ho lefella.
- .Ho khoneha: Boholo bo tloha ho 500 kVA (liindasteri tse nyane) ho isa ho 500 MVA (sekala sa ts'ebeliso).
- .Ho Bokgoni ba LitšenyeheloLitheko li fapana ho tloha ho.20,000∗∗(diyuniti tse nyane)ho isa ho∗∗20,000** (diyuniti tse nyane)ho isa ho **20,000∗∗(diyuniti tse nyane)ho isa ho∗∗1M+(mehlala e ikhethileng ea motlakase o phahameng).
.Likopo.
- .Limela tsa Motlakase: Li-transformer tse nyolohang ka mehato li nolofalletsa phetiso ea matla a mangata.
- .Liteishene tse nyenyane: Li-transformer tse theohelang fatše li netefatsa botsitso ba gridi le kabo e sireletsehileng.
- .Mekhoa ea Liindasteri: Tšehetsa mechine e boima ka phepelo e tšepahalang ea motlakase.
- .Matla a Nchafatsoang: Kopanya mapolasi a moya/letsatsi ka hara digridi, ho fokotsa diphetoho tsa tlhahiso.
.Ke Hobane'ng ha U Khetha Li-Transformers tsa JZP?.
Jwalo ka moetsi ya ka sehloohong wa China,Li-Transformer tsa JZPe ipabola ka:
- .Litharollo tse Ikhethileng: Meralo e etselitsoeng motlakase o itseng, bokgoni le ditlhoko tsa tikoloho.
- .Phano e PotlakilengTlhahiso e nolofalitsoeng e netefatsa hore projeke e phethoa ka nako.
- .Litheko tse Tlhōlisanoang: Mekhoa e ntlafalitsoeng ea tlhahiso e fana ka boleng bo holimo ka litefiso tse theko e tlaase.
Bakeng sa diindasteri tse behang pele bokgoni, polokeho le bokgoni ba ho atolosa, JZP Transformers e fana ka karabo e tiileng diphephetsong tsa motlakase tsa sejwalejwale.












