+86 18068001229 Tataiso ea Litšireletso tsa Electrostatic tsa Transformer (Li-E-shields)
E-shield ke eng?
Thebe ea motlakase e sa fetoheng ke lakane e tšesaane e tsamaisang motlakase e seng ea makenete. Thebe e ka ba koporo kapa aluminium. Lakane ena e tšesaane e tsamaea pakeng tsa li-winding tsa mantlha le tsa bobeli tsa transformer. Lakane e koiling ka 'ngoe e hokahana hammoho le mokhanni a le mong ea hokahanang le chassis ea transformer.

Li-e-shields li etsa eng ka har'a li-transformer?
Li-e-shields li fetisetsa litšitiso tse kotsi tsa motlakase hole le likhoele tsa transformer le lisebelisoa tsa elektroniki tse bonolo lits'ebetsong tsa motlakase. Sena se sireletsa transformer le sistimi e hokahantsoeng le eona.
A re talimeng sena ka botlalo re qala ka seo li-E-shields li se sireletsang khahlanong le sona.
Ho fokotseha ha maikutlo
Dipotoloho tse ngata tsa motlakase tsa sejwalejwale di angwa ke di-spikes tse sa feleng le lerata la mokgwa. E-shield e thelletsweng fatshe e fokotsa (e fokotsa) ditshitiso tsena.

Setšoantšo se kaholimo se ka letsohong le letšehali se bontša keketseho e tloaelehileng ea motlakase o fetohang ka potlako. Mofuta ona oa keketseho e matla ea motlakase o bakoa ke lisebelisoa tse tloaelehileng tsa ofisi joalo ka lik'homphieutha kapa li-fotokopi. Li-inverter le tsona ke mohloli o tloaelehileng oa li-spikes tse fetohang ka potlako. Setšoantšo se ka letsohong le letona se bontša mohlala oa lerata la mokhoa potolohong ea motlakase. Lerata la mokhoa le tloaelehile lipotolohong tsa elektroniki. Litsamaiso tse nang le terata e fokolang tse nang le tšireletso e sa lokelang ea cable hangata li na le lerata la mokhoa.
Jwale ha re shebeng kamoo E-shield e sebetsanang le ditshitiso tsena.
Ho kopanya ka matla
E-shield e thelletsweng fatshe e fokotsa kgokelo ya capacitive pakeng tsa di-winding tsa mantlha le tsa bobedi. Ho ena le ho hokahana le ho winding ha bobedi, ho winding ha mantlha ho hokahana le E-shield. E-shield e thelletsweng fatshe e fana ka tsela e tlase ya impedance ho ya fatshe. Ditshitiso tsa motlakase di fetisetswa hole le ho winding ha bobedi. Sena se boetse se sebetsa ho tloha pheletsong e nngwe ya transformer (ya bobedi ho ya ho ya mantlha).

Li-spikes tsa nakoana le lerata la modumo li ka senya li-transformer le lisebelisoa tse ling tsa motlakase. Thebe ea motlakase e sa fetoheng pakeng tsa likhoele tsa motlakase o phahameng le motlakase o tlase e fokotsa likotsi tse joalo. Ntho ea bohlokoa eo u lokelang ho e ela hloko ha u fa motlakase lisebelisoa tsa elektroniki tse bonolo.
Mehlala ea Li-Transformer tse Sebelisang E-shield
Li-Transformer tsa Letsatsi le Moea
Litšitiso tsa harmonic le phetoho e khethehileng ho tsoa ho li-inverter tsa letsatsi li fetisetsoa ho gridi ea lisebelisoa. Litšitiso tsena tsa motlakase li baka litlamorao tse kang tsa tšusumetso ho winding ea HV e fepang gridi. Li-spikes tsa overvoltage tse potlakileng ka lehlakoreng la lisebelisoa le tsona li ka fetela ho inverter. Liketsahalo tsena tsa overvoltage li ka senya likarolo tse bonolo tsa inverter. Li-e-shields li fana ka tšireletso bakeng sa transformer, grid le inverter.
Ithute haholoanyane ka boholo ba transformer ea letsatsi le litlhoko tsa moralo.
Khanna Transformer ea ho itšehla thajanas
Li-transformer tsa ho itšehla thajana li hahiloe ho mamella litšitiso tsa motlakase o phahameng oa maqhubu (harmonic). Litšitiso tse joalo li bakoa ke lisebelisoa tse kang li-drive tsa motlakase (kapa li-VFD). Kahoo lentsoe "drive" ka lebitso. Ntle le li-harmonics, li-drive tsa motlakase li ka boela tsa hlahisa litšitiso tse ling tsa motlakase (joalo ka lerata la mokhoa). Mona ke moo E-shield e sebetsang teng. Li-transformer tsa ho itšehla thajana tsa motlakase li kenyelletsa bonyane E-shield e le 'ngoe pakeng tsa li-coil tsa HV le LV. Lithebe tse ngata li ka sebelisoa hape. Li-e-shields li ka beoa pakeng tsa li-coil tsa ka hare le maoto a mantlha.
Lisebelisoa tse nang le mathata a motlakase (joalo ka li-spikes tse fetohang le lerata la mokhoa) li rua molemo ho transformer e nang le E-shield. E-shields ha li theko e tlase, 'me li fana ka phaello e kholo matseteng moo mathata a boleng ba motlakase e leng tšokelo.