+86 18068001229 Mesebetsi le Ts'ebeliso ea Li-Transformer tse Ileng tsa Kenngoa ka Oli tsa Mekhahlelo e Meraro
Mesebetsi ea Bohlokoa
.
Phetoho ea Voltage le Phetiso ea Matla
Transformer e qoelitsoeng ka oli ea mekhahlelo e meraros e sebelisa induction ea motlakase ho phahamisa kapa ho theola li-voltage tsa AC, e leng lisebelisoa tsa bohlokoa lits'ebetsong tsa motlakase ho hokahanya li-grid tsa maemo a fapaneng a motlakase. Mohlala, li phahamisa li-voltage tsa tlhahiso ea jenereithara (mohlala, 6kV kapa 10kV) ho li-voltage tsa boemo ba phetisetso (mohlala, 220kV kapa ho feta) bakeng sa ho fana ka motlakase o hole kapa ho fokotsa motlakase o nang le motlakase o phahameng ho li-voltage tsa boemo ba kabo (mohlala, 10kV/0.4kV) bakeng sa basebelisi ba ho qetela.
.
Ho kenya mocheso le ho qhala mocheso
Oli ea transformer e sebetsa e le sesebelisoa sa ho thibela mocheso le ho pholisa:
Ho thibela ho ruruha: Matla a phahameng a dielectric a oli (a fetang moea haholo) a thibela lipotoloho tse kgutshwane pakeng tsa di-winding le cores, a arola mongobo le ditshila, mme a diehisa ho tsofala ha ho thibela ho ruruha.
.
Ho Pholisa: Mocheso o hlahisoang ke li-winding le li-core o fetisetsoa oling, e potolohang ka tlhaho kapa ka litsamaiso tse qobelloang (mohlala, lifene, lipompo) ho ea ho li-radiator kapa libaka tsa tanka, ho boloka mocheso o sireletsehileng oa ts'ebetso (hangata ≤85°C bakeng sa oli e kaholimo)
.
Polokeho le Tsitsiso
Ho Hanela Potoloho e Khutšoanyane: Meaho e qoelitsoeng ka oli ka botlalo e ntlafatsa matla a mechini, e tlatselletsoang ke li-relay tsa khase le li-vent tse thibelang ho phatloha ho lokolla khatello ka mokhoa o sireletsehileng nakong ea liphoso tsa kahare.
.
Taolo ea Voltage: Li-pompo tse fetolang thepa ha li jaroa kapa ha li sa jaroa li fetola motlakase o hlahisoang (± 5%) ho tsitsisa liphetoho tsa gridi tse bakoang ke kopanyo ea matla a nchafatsoang kapa liphetoho tsa mojaro.
.
Ho Ikamahanya le Tikoloho
Ts'ebetso ea Sebaka se Phahameng: Bakeng sa libaka tse phahameng tse fetang limithara tse 3,000, meralo e kenyelletsa lifene tse kholo tsa ho pholisa kapa ho qhala mocheso ho ntlafalitsoeng ho lefella pholiso e fokotsehileng ka lebaka la khatello e tlase ea moea.
.
Theknoloji ea ho Tiea: Litanka tse entsoeng ka masenke kapa li-conservator tse entsoeng ka capsule li fokotsa ho kopana ha oli le moea, li eketsa linako tsa tlhokomelo le nako ea ts'ebetso.
.
Litšebeliso tsa Bohlokoa
Meralo ea Motheo ea Matla
Tlhahiso le Liteishene tse Nyenyane: Eketsa motlakase liteisheneng tsa motlakase (mohlala, 10kV ho isa ho 220kV) bakeng sa phetiso le motlakase o theotsoeng liteisheneng tse Nyenyane tsa terminal (mohlala, 35kV ho isa ho 0.4kV) bakeng sa ts'ebeliso ea indasteri/metse ea litoropo.
.
Kgokelo ya Gridi: Ho thusa kabo botjha ya eneji ho pholletsa le dibaka, ho netefatsa hore ho na le maemo a leka-lekaneng a phepelo le tlhokeho.
Makala a Indasteri le Matla
Masimo a Oli le Merafo: Fana ka motlakase o tsitsitseng bakeng sa mechine ea ho cheka, lisebelisoa tsa ho ntša oli le libaka tse hole libakeng tse thata.
.
Tšepe le Lik'hemik'hale: Fana ka matla a motlakase o phahameng (mohlala, 10kV/35kV) ho lisele tsa electrolytic, liontong le lienjene tse kholo
.
Kaho le Litšebeletso tsa Sechaba
Matla a Nakoana: A sebediswa dibakeng tsa kaho, diketsahalong, kapa maemong a tshohanyetso bakeng sa kabo ya motlakase e potlakileng le e tshepahalang
.
Lipalangoang tsa Terene: Phepelo ea matla a ho hula (mohlala, 35kV/1.5kV) bakeng sa litsamaiso tsa terene tsa metro le tsa lebelo le phahameng
.
Li-Renewable & Smart Grids
Kopanyo ea Letsatsi/Moea: Eketsa matla a nchafatsoang a motlakase o tlase (mohlala, 0.69kV) ho ea maemong a ho kena ka gridi (mohlala, 35kV) bakeng sa phepelo e sebetsang hantle
.
Taolo ea Voltage e Matla: Ikamahanye le ho feto-fetoha ha matla a ajoang, ho boloka botsitso ba gridi ka liphetoho tsa ho pompo ka nako ea sebele
.
Tsoelo-pele ea Theknoloji le Mekhoa ea Khetho
Lintlafatso tsa Bokgoni ba Matla
Mefuta ea sejoale-joale (mohlala, letoto la S13/S22) e fokotsa tahlehelo e sa jareng ka >30% ka ho ntlafatsa lamination ea mantlha (mohlala, li-alloy tse sa fetoheng) le meralo ea ho winding, e latela maemo a GB 20052-2024.
.
Ntlafatso ea Tikoloho
Oli tse Bolang: Nka sebaka sa oli ea diminerale ka li-ester tse thehiloeng limela (100% e bola, flashpoint ≥350°C) ho fokotsa likotsi tsa mollo le tšusumetso ea tikoloho.
.
Tlhokomelo e Bohlale: Li-sensor tse kopaneng tsa IoT li latela boleng ba oli, mocheso le ho ntšoa ha oli ka karolo bakeng sa tlhokomelo e boletsoeng esale pele.
.
Liparamente tsa Khetho
Bokgoni: 30kVA ho isa ho 20,000kVA, ka diyuniti tse kgolo bakeng sa meroalo ya diindasteri
.
Mekhoa ea ho Pholisa:
ONAN (Sepholi se Itšireletsang ka Oli): Bokgoni bo bonyenyane (
OFAF(Ho Pholisa Oli/Moea ka Matla): Li-transformer tse nang le bokhoni bo phahameng (>20,000kVA)
.
Sehlopha sa ho Sireletsa: Sehlopha sa H (180°C) bakeng sa dibaka tse feteletseng
.
Qetello
Li-transformer tse qoelitsoeng ka oli tsa mekhahlelo e meraro li ntse li le bohlokoa haholo litsamaisong tsa motlakase tsa sejoale-joale ka lebaka la bokhoni ba tsona, botšepehi le ho ikamahanya le maemo. Lintlafatso tsa thepa e mosa tikolohong, tlhahlobo e bohlale, le meralo e menyenyane li tsamaisana le lipheo tsa botsitso ba lefats'e, ho netefatsa bohlokoa bo tsoelang pele mererong ea phetoho ea matla.