+86 18068001229 Li-Transformer tsa Mofuta o Omileng Khahlanong le tse Kenngoeng ka Oli: Tataiso e Felletseng ea Papiso
I. Liphapang tsa Bohlokoa
1. Moralo le ho kenya mocheso
Transformer ea Mofuta o Omilengs:
Ho thibela ho ruruha: Ho lahla resin ea epoxy kapa ho thibela ho ruruha ho sa koaheloang ka har'a capsule (mohlala, pampiri ea Nomex).
Sebopeho: Methapo e bonahalang ya motheo/mapheo a nang le dithupa tsa rabara tsa silicone.
Transformer e qoelitsoeng ka olis:
Ho thibela ho ruruha: Oli ea diminerale kapa ea maiketsetso ea ester; e qoelisoa ka botlalo ka tankeng.
Sebopeho: Tanka e koetsoeng ka lithupa tsa porcelain.
2. Bokgoni le Methati ya Motlakase

II. Papiso ea Tshebetso le Litšenyehelo
1. Bokgoni ba ho Phodisa le ho Jara Moro o Feteletseng
Bokgoni ba ho Pholisa:
Mofuta o omileng: Pholiso ea moea ea tlhaho/e qobelloang (bokhoni bo fokolang).
Ho qoelisoa ka oli: Ho potoloha ha oli (ho molemo bakeng sa meroalo e phahameng e tšoarellang nako e telele).
Mamello e Feteletseng:
Mofuta o omileng: ≤1.5x bokgoni bo lekantsoeng (nako e kgutshwane).
Ho qoelisoa ka oli: 30% ea ho feta tekano ka hora e le 'ngoe.
2. Litšenyehelo le Tlhokomelo

III. Maemo a Ts'ebeliso
1. Linyeoe tsa Tšebeliso ea Mofuta o Omileng tse Tlamang
Polokeho ea Mollo: Lipetlele, literata tse tsamaeang ka tlas'a lefatše, mehaho e metelele (epoxy e thibelang malakabe).
Litšitiso tsa Sebaka: Likamore tse ka tlas'a lefatše, liteishene tse nyane (ka boholo bo bonyenyane ka 20%).
Libaka tse Senolang Tikoloho: Moralo o se nang oli o lumellanang le RoHS.
2. Maemo a Ratwang a Kentsweng ka Oli
Litlhoko tse Phahameng tsa Motlakase: Limela tsa mocheso, lirapa tsa indasteri (≥10MVA).
Libaka tse mongobo: Libaka tse lebōpong la leoatle, merafo (oli e hanela mongobo).
Maemo a lehodimo a feteletseng: Tshebetso e tsitsitseng ho tloha ho -40°C ho isa ho 45°C.
IV. Mokgwa wa Mosebetsi wa Kgetho
Hlalosa Litlhoko:Mofuta oa mojaro (o tsoelang pele/o tšosang/o lumellanang), tikoloho (mongobo/sebaka).
Bala Bokgoni:S = Matla a ho Jara (kW) / Ntlha ea Matla.
Likarolo tsa Papali:
Polokeho ea mollo → Mofuta o omileng (letoto la SCB)
Bokgoni/motlakase o phahameng → E qoelitsoeng ka oli (letoto la S13-M)
Melemo ea Litšenyehelo:Nako e telele → Mofuta o omileng (TCO e tlase); nako e kgutshwane → E qoelisoang ka oli (CAPEX e tlase).
V. Mekhoa le Mekhoa e Mecha
Mofuta o omileng:
Tlhokomelo e Bohlale: Li-sensor tse sebelisang IoT (mohlala, Siemens CoolBlue).
Voltage e Phahameng: Mehlala ea liteko ea 66kV bakeng sa mapolasi a moea a lebōpong la leoatle.
Ho qoelisoa ka oli:
Lintlafatso tsa Tikoloho: oli ea β (sebaka sa mollo ≥300°C) e nkang sebaka sa oli ea diminerale.
Moralo o Monyenyane: Ditanka tse kwaletsweng ka makotikoti (tse nang le karolo e nyane ya 15%).
Qetello
Li-transformer tsa mofuta o omileng le tse qoelitsoeng ka oli li sebetsa 'moho e le litharollo tse tlatsetsang. Ka melaoana e tiileng (mohlala, EU Tier 3), mefuta e omileng e busa makala a khoebo, ha e qoelitsoeng ka oli e ntse e le ea bohlokoa bakeng sa meralo ea motheo ea matla. Bakeng sa khetho e ntle ka ho fetisisa, leka-lekanya litlhaloso tsa tekheniki le litšenyehelo tsa potoloho ea bophelo.