+86 18068001229 Li-Transformer tsa Kabo: Likarolo tsa Bohlokoa le Melao-motheo ea Ts'ebetso
Transformer ea Kabos e sebetsa e le meralo ea motheo ea bohlokoa li-grid tsa motlakase tsa sejoale-joale, e theola ka katleho lithapo tsa phetiso ea motlakase o phahameng (hangata 11-33 kV) ho li-voltage tse ka sebelisoang tsa tšebeletso (120-480 V) bakeng sa bareki ba bolulo, ba khoebo le ba indasteri.
Disebediswa tsena tsa motlakase o sa fetoheng di sebetsa ka melaomotheo ya motheo ya ho kenya motlakase ka motlakase ha ka nako e ts'oanang di kenyeletsa dikarolo tse tswetseng pele tsa boenjiniere bakeng sa ho tshepahala le polokeho.
.1. Mekaniki ea Ts'ebetso.
Tshebetso ya phetoho ya motlakase e itshetlehile hodima induction ya motlakase pakeng tsa di-winding tsa mantlha le tsa bobedi. Ha motlakase o fapanyetsana o phalla ka hara ho winding ya mantlha ya motlakase o phahameng, o hlahisa phallo ya makenete e fetohang ka nako ka hara motheo wa tshepe ya silicon e laminated. Kopanyo ena ya makenete e baka voltage e lekanang ho winding ya bobedi, e laolwang ke karolelano ya di-turns (N₁/N₂) ho ya ka Molao wa Faraday wa Induction.
Likamano tsa lipalo li ka hlalosoa ka tsela ena:
V₁/V₂ = N₁/N₂ = k (karolelano ea ho reteleha)
I₁/I₂ = N₂/N₁ (karolelano ea hona joale e fapaneng le karolelano ea motlakase)
.2. Moralo oa Meaho.
Mekhoa ea sejoale-joale ea ts'ebetso e na le litlhophiso tse ntlafalitsoeng:
- .Kopano ea mantlha: Li-core tsa tšepe tsa silicon tse shebaneng le lijo-thollo tse laminated li fokotsa tahlehelo ea hona joale ea eddy ha li ntse li boloka matla a khoheli a kenella
- .Mekhoa ea ho Pholisa:
- Mefuta e qoelitsoeng ka oli (e tloaelehileng bakeng sa ho kenya kantle) e sebelisa oli ea transformer bakeng sa taolo ea mocheso le ho thibela ho ruruha ha dielectric
- Transformer ea Mofuta o Omilengs (e loketse lits'ebetso tsa ka tlung) sebelisa moea o pholileng ka polokeho e ntlafalitsoeng ea mollo
- .Mekhoa ea Tšireletso: Dithibelo tse kopaneng tsa ho thiba maqhubu, di-relay tsa mocheso, le di-valve tsa ho imolla kgatello di netefatsa polokeho ya tshebetso kgahlanong le maqhubu a feteletseng le kgatello ya tikoloho.
.3. Litšobotsi tsa Tshebetso.
- .Mefuta ea Bokgoni: E fihlella katleho ea 95-99% tlas'a maemo a matle a ho kenya ka ho fokotsa tahlehelo ea mantlha (hysteresis le maqhubu a eddy)
- .Likhetho tsa Bokhoni: E fumaneha ho tloha ho 50 kVA ho isa ho 25,000 kVA, ka meralo e menyenyane e nolofalletsang ho kenya lipalo kapa ho kenya li-pad
- .Taolo ea Motlakase: Theknoloji e tsoetseng pele ea OLTC (On-Load Tap Changer) e nolofalletsa taolo ea motlakase oa ±10% ntle le litšitiso tsa litšebeletso.
.4. Mekhoa e Mecha ea Polokeho.
Diyuniti tsa sejoale-joale li kenyelletsa likarolo tse ngata tse sireletsang:
- Tšireletso e feteletseng ka ho sebelisa litšoantšo tsa mocheso le li-sensor tsa mocheso tse kobehileng
- Tekanyetso ea hona joale ea potoloho e khuts'oane e sebelisang li-fuse tse fokotsang hona joale
- Ho hatelloa ha maqhubu ka li-varistor tsa tšepe-oxide (MOVs) le li-winding tse sirelelitsoeng
.5. Mehopolo ea Tlhokomelo.
Leha ho hlokahala tlhokomelo e nyane ha ho bapisoa le mechini e potolohang, tlhahlobo ea nako le nako e shebana le:
- Teko ea matla a dielektri ea oli e thibelang mocheso (bakeng sa mefuta e qoelitsoeng ka oli)
- Tlhokomelo e sa fellang ea ho ntša metsi mapheong a motlakase o phahameng
- Tlhahlobo ea boemo ba bushing ho sebelisoa thermography ea infrared
Litharollo tsena tse entsoeng ka boenjiniere li bontša ho kopanngoa ha melao-motheo ea khale ea motlakase le lisebelisoa tsa motlakase tsa sejoale-joale, ho netefatsa kabo ea matla e sebetsang hantle le e tšepahalang ho pholletsa le meralo e fapaneng ea gridi. Bakeng sa lits'ebetso tse ikhethileng joalo ka kopanyo ea matla a nchafatsoang kapa litsamaiso tse bohlale tsa gridi, meralo e tsoetseng pele e kenyelletsang li-cores tsa tšepe tse se nang sebopeho e ntlafatsa ts'ebetso ka tahlehelo e tlase haholo ea ho se be le mojaro.