+86 18068001229 Tataiso e Felletseng ea Barekisi ba Li-Auto: Melao-motheo ea Mosebetsi, Mefuta le Litšebeliso
Li-autoregulator, ho kenyeletsoa li-autotransformer le li-automatic Molaoli oa Motlakases (AVR), ke disebediswa tsa bohlokwa bakeng sa ho boloka maemo a tsitsitseng a motlakase ditsamaisong tse fapaneng tsa motlakase. Le hoja mantswe a kang "autoregulator" a ka utlwahala a sa tlwaeleha ho batho bao e seng ditsebi, disebediswa tsena di sebetsana le diphephetso tsa lefatshe ka bophara taolong ya matla. Ka tlase ke tlhaloso e qaqileng ya melaomotheo ya tsona ya tshebetso, dihlopha le dikarolo tsa bohlokwa.
.1. Melao-motheo ea Mosebetsi.
Li-autoregulator li sebetsa kaphetoho ea motlakase e tsoelang peleka ho fetola diparamitha tsa tshebetso tsa transformer.
- .Moralo oa MotheoMefuta e 'meli ea mantlha e sebelisoa hangata:
- .Sekoahelo sa lesale: E nyane ebile e sebetsa hantle, e loketse lits'ebetso tsa motlakase o tlase ho isa ho o mahareng.
- .Konopo ea Kholomo: E loketse litsamaiso tse nang le bokhoni bo phahameng ka lebaka la ho qhalana ha mocheso ho eketsehileng.
- .Taolo ea Motlakase: Ka ho fetola karolelano ea ho reteleha ha transformer (mohlala, ho tsamaisa borashe ba khabone ho latela coil), motlakase o hlahisoang oa tsitsisoa. Bakeng sa li-autotransformers, sena se kenyelletsa ho aba motlakase hape ho pholletsa le li-winding tse arolelanoang.
.2. Mefuta e Tloaelehileng.
Li-Autoregulators li arotsoe ka lihlopha ho latela moralo le ts'ebeliso:
| .Mofuta. | .Tlhaloso. | .Likopo. |
| .Autotransformer. | Transformer e kobehang ka lesoba le le leng bakeng sa phetoho ea motlakase o nyolohang/o theohelang. E sebetsa hantle ebile e theko e tlase. | Mechini ea indasteri, li-grid tsa motlakase. |
| .Taolo ea Voltage e Iketsang (AVR). | E laola motlakase o tswang ka elektroniki ka di-feedback loops. E bohlokwa bakeng sa di-elektroniki tse bonolo. | Lijenereithara, litsamaiso tsa UPS, litsi tsa data. |
| .Taolo ea Likoloi tsa Servo. | E sebelisa liphetoho tsa mechini (mohlala, li-switch tsa pompo) bakeng sa taolo e nepahetseng ea motlakase. E loketse meroalo e feto-fetohang. | Lilaboratori, lisebelisoa tsa bongaka. |
.3. Melemo ea Bohlokoa.
- .Moralo o Monyenyane: Li-Autotransformer li hloka sebaka se ka tlase ho 30–50% ho feta li-transformer tse tloaelehileng ka lebaka la ho kopana ha li-winding tse arolelanoang.
- .Bokgoni bo Phahameng: Tahlehelo e fokotseha (e ka tlase ho 1–2%) ka ho fokotseha ha tšebeliso ea koporo.
- .Ho feto-fetoha ha maemo: E tšehetsa litsamaiso tsa AC le DC, ka mehlala e sebetsanang le li-voltage ho tloha ho 160V ho isa ho 450V.
.4. Mekhoa ea 'Maraka.
- .Karolo e Laolang: Balaoli ba motlakase o sa fetoheng ba etella pele 'marakeng ka lebaka la botšepehi le ho nepahala.
- .Bakhanni ba Kholo: Tlhokeho e ntseng e eketseha ya eneji e ntjhafatswang, meralo ya motheo ya ho tjhaja motlakase wa motlakase wa motlakase, le digridi tse bohlale.
.5. Mehopolo ea Theko.
Ha o kgetha autoregulator:
- .Bokgoni: Kopanya sesebediswa le ditlhoko tsa mojaro o phahameng (mohlala, 20kVA bakeng sa dilaboratori tse nyane, >1MVA bakeng sa difeme).
- .Ho Ikamahanya le Tikoloho: Khetha mehlala e lekantsoeng ke IP bakeng sa libaka tse mongobo kapa tse lerōle.
- .Lisetifikeiti: Netefatsa hore ho latela maemo a IEC/UL bakeng sa polokeho le ts'ebetso.
Bakeng sa litlhoko tse ikhethileng, buisana le bahlahisi ba fanang ka litharollo tsa OEM/ODM ho etsa maemo a motlakase le litlhophiso tsa ho o kenya.