Tlhahlobo ea Liphoso tsa Transformer le Mekhoa ea ho Tharolla Mathata

 

Li-transformer, e le disebediswa tsa mantlha ditsamaisong tsa motlakase, di etsa mesebetsi ya bohlokwa ho kenyeletswa le phetoho ya motlakase, taolo ya hajwale, le ho ikarola ha motlakase. Tshebetso ya tsona e tsitsitseng ke ya bohlokwa ho netefatseng polokeho le bokgoni ba marangrang a motlakase. Dikarolo tse latelang di fana ka tlhahlobo e qaqileng ya tsamaiso ya tshebetso ya transformer, mekgwa e tlwaelehileng ya ho lemoha diphoso, le mekgwa ya ho rarolla mathata.

 

 

Mekhoa ea ho Lokisetsa le ho Hlahloba Phetoho ea Transformer

 

Pele ho kenngwa tshebetsong transformer, ho lokela ho etswa tlhahlobo e felletseng ho netefatsa hore e se e loketse ho sebetsa hantle:

 

Tlhahlobo ea Sehokelo le Khokahano: Etsa tlhahlobo e felletseng ea lihokelo tsohle tse ka hare le ka ntle ho transformer, haholo-holo libakeng tsa bohlokoa tsa khokahano tse kang li-terminal tsa wiring le li-busbars. Netefatsa hore torque e sebelisoa hantle nakong ea ho tiisa ho thibela tšenyo ea khoele, ha u ntse u qoba ho tšoaroa ke ho se lumellane ha thepa pakeng tsa liboutu le linate.

 

Netefatso ea ho Kenya Likarolo: Netefatsa ho kenngoa hape ka nepo ha likarolo tsohle tse qhaqhollotsoeng nakong ea lipalangoang kapa ho kenngoa, hlahloba liphaephe tsa ho pholisa tsa ka hare bakeng sa maemo a se nang lithōle, 'me u netefatse ho ba sieo ha lisebelisoa tse setseng ka har'a sekwahelo sa transformer.

 

Tlhahlobo ea Sesebelisoa sa Taolo ea Mocheso: Netefatsa hore likhoele tsa taolo bakeng sa balaoli ba mocheso le li-index li fetiselitsoe hole le libaka tsa koili le likarolo tse phelang. Tiisa hape ha ho hlokahala ho thibela tšitiso.

 

Sistimi ea ho Pholisale Tlhahlobo ea Lisebelisoa tse Thusang: Netefatsa ts'ebetso e nepahetseng ea lifene tse pholileng, lisebelisoa tsa taolo ea mocheso, le litsamaiso tse thusang. Netefatsa ka ho khetheha tataiso ea ho potoloha ha fene ho netefatsa hore phallo ea moea e lebisitsoe holimo ho tloha botlaaseng ba li-winding tsa transformer.

 

Liteko tsa Pele ho Phetoho

 

Ho netefatsa ho latela litlhaloso tsa moralo, liteko tse latelang tse tlamang li tla etsoa pele ho laeloa hore transformer e sebetse:

 

Tekanyo ea Khanyetso ea DC: Etsa litekanyo tsa khanyetso e kobehileng libakeng tsohle tsa ho pompo ho netefatsa ho latela litlhaloso tsa moralo.

 

Tekanyo ea Tekanyo ea Motlakase: Netefatsa ho nepahala haphetoho ea motlakasedikarolelano le ho netefatsa ho nepahala ha tlhaloso ea sehlopha sa vector ka ho hlahloba polarity le tatellano ea mekhahlelo.

 

Teko ea ho Hanela ho Kena ha Insulation: Etsa liteko tsa dielectric pakeng tsa motheo le meaho ea ho khomarela ho netefatsa botšepehi ba ho kenngoe ha insulation.

 

Teko ea ho Hanela ho Kena ha Mabili: Lekanya ho hanela ho kenngoe ha mabili ho netefatsa ho latela melao ea polokeho ea motlakase.

 

Teko ea ho Ikokobetsa Maqhubu a Matla: Bakeng sa li-transformer tse lokisitsoeng tšimong tse khutlelang ts'ebetsong, teko ea motlakase oa ho mamella dielectric e tla etsoa ho 80% ea boemo ba motlakase oa teko ea fektheri ea pele, ho latela litlhoko tsa IEC 60076-3 Clause 10.

 

Mehato ea ho itšireletsa bakeng sa ts'ebetso e sireletsehileng ea li-transformer

 

Tlhahlobo ea Sistimi ea ho Theoha: Etsa tlhahlobo e matla ea sistimi ea ho theoha ka mor'a ho e kenya ho netefatsa ts'ebetso ea eona e sireletsehileng le e tšepahalang.

 

Litšitiso tsa Polokeho: Li-transformer tse se nang tšireletso ea kampetsoeng li tla hlomelloa ka litšitiso tsa ho itšehla thajana ho thibela ho kopana ka kotloloho le likarolo tse phelang le ho fokotsa likotsi tsa ho bolaoa ke motlakase.

 

Ts'ebetso ke Basebetsi ba Tšoanelehang: Ho kenya, ho laela le ho hlokomela li-transformer ho tla etsoa ke litsebi tse nang le mangolo feela ho netefatsa hore ho latela maemo a ts'ebetso le melaoana ea polokeho.

 

Mehato ea ho Hloka Transformer

 

Ho Kenya Tshebetso Sistimi ya Taolo ya Mocheso: Pele o kenya matla, leka le ho leka sesebelisoa sa taolo ya mocheso kapa yuniti ya pontsho ya mocheso ho netefatsa tshebetso e nepahetseng.

 

Mokhoa oa ho Kenya Matla: Koala li-circuit breaker ka transformer maemong a sa jareng. Kenya tšebetsong relay ea tšireletso ea overcurrent hang-hang nakong ea ho kenya matla ho fokotsa litlamorao tsa hona joale tse kenang.

 

Keketseho e nyane hanyane ka hanyane ea mojaro: Kamora ho kenngoa tšebetsong, mojaro o lokela ho eketsoa butle-butle le ho beoa leihlo bakeng sa melumo efe kapa efe e sa tloaelehang kapa ho thothomela ho qoba keketseho e potlakileng ea mojaro.

 

Protocol ea ho Fokotsa Mongobo: Bakeng sa li-transformer tse se nang matla tse pepesetsoeng mongobo o potolohileng >80% RH.

 

Liphoso tse Tloaelehileng tsa Transformer le Liketso tsa Tokiso

 

Phoso ea ho futhumatsa ho feta tekano: Sena se kenyelletsa ho chesa ho feteletseng sebakeng se itseng le ho phahama ho feteletseng ha mocheso ka kakaretso. Hlahloba maemo a mojaro, motlakase le ho qhalana ha mocheso.

 

Liphoso tsa ho ntša metsi: Li ka hlaha e le ho ntša metsi ka karolo e itseng, ho ntša metsi ka har'a arc, kapa ho ntša metsi ka har'a arc; hangata li amahanngoa le mathata a ho thibela ho ruruha.

 

Phoso ea ho kenya thepa ka har'a insulation: Joalo ka ho senyeha ha ho kenya thepa ka har'a insulation kapa ho senyeha ha ts'ebetso ea ho kenya thepa ka har'a insulation; thepa e senyehileng ea ho kenya thepa ka har'a insulation e tlameha ho hlahlojoa kapele le ho nkeloa sebaka.

 

Liphoso tse ling: Ho kenyeletsoa lerata le sa tloaelehang, ho se sebetse hantle ha ts'ireletso, ho lutla ha oli, jj.

 

Mekhoa ea ho lemoha liphoso:

 

Tlhahlobo ea pono: Hlahloba phallo ea mojaro, liphetoho tsa 'mala oa oli, le ponahalo ea kantle bakeng sa lintho tse sa tloaelehang (mohlala, ho lutla ha oli, ho fetoha ha 'mala).

 

Tlhokomelo ea kutlo: Mamela melumo e sa tloaelehang nakong ea ts'ebetso (mohlala, ho lla ho sa lekaneng, ho phatloha, kapa melumo e hlabang).

 

Tekanyo ea motlakase: Lekanya khanyetso ea DC ea mekhahlelo e meraro le khanyetso ea ho futhumatsa mocheso ho lekola hore na boleng bo oela ka har'a meeli e tloaelehileng.

 

 

Phoso ea Ts'ebetso ea Insulation

 

Phokotso ea ts'ebetso ea ho thibela ho ruruha ke phoso e tloaelehileng ea li-transformer, haholo-holo libakeng tse mongobo. Teko ea ho hanyetsa ho thibela ho ruruha e lokela ho etsoa tlas'a maemo a loketseng, ka litekanyetso tse latelang tse tloaelehileng:

 

HV ho ea ho LV le ho sila: ≥ 300 M Ω (10kV), ≥ 1000 M Ω (35kV).

HV ho ea fatše: ≥100 MΩ.

Bakeng sa ‌core/lisebelisoa tsa fatše‌, sheba litokomane tsa moetsi.

 

Haeba transformer e bontša ho kenella ha mongobo kapa ho kolobisoa ha oona (mohlala, marotholi a bonahalang holim'a libaka tsa resin ea epoxy kapa likarolo tsa mantlha), ho oma hang-hang hoa hlokahala ho khutlisa botšepehi ba insulation, ho sa tsotelehe boleng ba eona ba hona joale ba ho hanyetsa insulation.

 

 

Protokhole ea ho Fokotsa Lerata le sa Tloaelehang la Transformer

 

Ts'ebetso e tloaelehileng ea transformer e tla hlahisa molumo o llang o fapaneng le mojaro. Haeba ho na le molumo o sa tloaelehang, ho hlokahala tlhahlobo e 'ngoe hape:

 

Ho hlepha ha pelo: Ho hlahisa lerata le llang kapa le llang ka lebaka la ho lla ho sa sireletsehang kapa torque e sa lekaneng ea bolt.

 

Motsoako o sa koaheloang: E ​​hlahisa melumo e hlabang ea ho ntša metsi ho tsoa ho bokellaneng ha motlakase pakeng tsa motsoako le tanka.

 

Liphoso tsa ho kopana le Switch: E baka ho lla kapa ho petsoha ha maqhubu a pompo kapa manonyeletso a busbar.

 

Ho ntša loto/ho kobeha: Ho ntša li-arcs tse utloahalang tse tsoang ho ho senyeha ha insulation libakeng tse nang le motlakase o phahameng.

 

Lihlahla tse silafetseng: E ​​baka ho ntšoa ha corona ka lebaka la ho bokellana ha oli/likaroloana holim'a metsi.

 

Ho rarolla mathata a ho se sebetse hantle ha taolo ea mocheso

 

Ho hloleha ho Bulela: Hlahloba phepelo ea motlakase, li-fuse, likhokahano tsa terminal, le boemo ba switch.

 

Ha ho Pontšo ea Mocheso: Hlahloba khokahano ea sensor le khanyetso.

 

Ho kheloha ha mocheso: Hlahloba ho kenngwa ha di-sensor le mehlodi ya tshitiso.

 

Ho Hlōleha ha Puisano: Hlahloba mohala oa puisano 'me u ikopanye le tšehetso ea tekheniki ea mofani oa thepa.

 

Litharollo tsa ho Fokotsa ho se Leka-lekane ha Voltage ea Mekhahlelo e Meraro

 

Ho se leka-lekane ha motlakase oa mekhahlelo e meraro hangata ho bakoa ke liphoso tsa ho thella ha mobu kapa ho se leka-lekane ha mojaro. Litharollo li kenyelletsa:

 

Ho Theolela Metsi a Mangata Bakeng sa Phokotso ea Tahlehelo ea Mohala o sa Nepahaleng: Kenya tšebetsong ho theela metsi a mangata marangrang a kabo ea motlakase o tlase ho fokotsa tahlehelo ea matla a mohala o sa nepahaleng ka ho ntlafatsa litsela tsa ho khutla ha hona joale le ho fokotsa impedance.

 

Transformer ea Mokhahlelo o le Mong Ho Sebetsa: Sebelisa li-transformer tsa mohato o le mong bakeng sa libaka tse nang le meroalo e meholo ea mohato o le mong (mohlala, libaka tsa bolulo) ho arola maqhubu a sa leka-lekanang le ho thibela tšitiso ea harmonic.

 

Tlhokomelo le ho Leka-lekanya Mojaro: Etsa litekanyo tsa mojaro nako le nako u sebelisa li-clamp metres ho lekanya ho kheloha ha hona joale lipakeng tsa mekhahlelo.

 

Phekolo ea Phetoho ea 'Mala oa Oli le Tsamaiso ea ho Dutla ha Molumo

 

Ho fifala ha oli: Ho fifala ha oli (mohlala, amber e fetoha sootho/botsho) ho bontša ho monngoa ha mongobo le ho senyeha ha oxidation, e leng se lebisang ho fokotseng matla a dielectric le ho eketseha ha acidity. Nkela oli e senyehileng sebaka kapele ho thibela ho tsofala ha insulation ka potlako le ho hloleha ha lisebelisoa.

 

Ho Dutla ha Oli: Etsa qeto ea hore na u tsoele pele ho sebetsa le ho hlophisa tlhokomelo ho latela boemo ba ho dutla ha oli, kapa u e koale hang-hang 'me u tlatse oli hape.

 

Qetellong, Ts'ebetso e tsitsitseng ea li-transformer ke motheo oa ts'epo ea sistimi ea motlakase. Ka tlhahlobo e hlokolosi, tlhahlobo/tharollo ea liphoso kapele, le tlhokomelo e potlakileng, bophelo ba ts'ebeletso ea li-transformer bo ka atolosoa ka katleho, sekhahla sa ho hloleha se fokotsoe, 'me polokeho/bokgoni ba litsamaiso tsa motlakase bo tiisitsoe.